Crosley CAMHE18B2 Use & Care Manual Download Page 10

Fig.17A

8

INSTALLATION  INSTRUCTIONS

4. Attach the top angle to window frame: Use a 3/32
    drill bit to drill one hole through the hole in the
    middle of top angle into the window frame, and
    drive one 3/ 4  (or 1/ 2  ) HEX-HEAD locking screw 
    through hole in the middle of top angle into the 
    window frame as shown (Fig.17A).

7

Attach Window Filler Panels to

Window Frame

1. Extend the window filler panels out against the 
    window frame.
2. Use a 1/8" drill bit to drill a starter hole through the 
    hole in the top leg of each window filler panel and 
    into the window sash (Fig. 18A  and Fig. 18B). 
   Connect with one 3/ 4  (or 1/ 2") long hex head 
   screw.

8

1. Trim sash seal to fit window width. Insert into
     space  between upper and lower sashes(Fig.18).

Window Sash Seal

Fig.18

Install Window Sash Seal and 

Safety Lock 

9

Install Chassis into Cabinet 

and Install Front to Unit

1. Lift air conditioner and carefully slide into 
    cabinet leaving 6 inches protruding.
2. DO NOT push on controls or finned coils.
3. Be sure chassis is firmly seated towards rear
     of cabinet.
4. Installation of front is the reverse of removal 
    outlined in Section 1.

INSTALL R1 HARDWARE (only be
applicable to Energy star models )

In order to minimize air leaks and ensure optimal 
insulation, it is necessary to install the included R1
hardware to the side curtain. Follow the instructions 
below. 
Step 1. After the unit is installed to the window, 
measure the inner width of the side curtain as shown 
(Fig.20).

10

Fig.18A

A.3/ 4  (or 1/2 ) long hex head screw
B. Left-hand Window Filler
     Panel Top Leg
C. Window channel

Fig.18B

A.3/ 4 (or1/2  ) long hex head screw

3/ 4  (or 1/ 2 ) long
HEX-HEAD
SCREW

Safety Lock

3 4 (or1

 )Long

Hex-head Screws

/2 

Fig.19

2. Attach right angle safety lock (Fig.19).

Step 2. Remark a line on the provide R1 insulation 
panel according to a length 1/8  (3mm) less than the 
measured width in step 1, then cut the R1 insulation 
panel along the line (Fig.12).

Summary of Contents for CAMHE18B2

Page 1: ...USE CARE GUIDE 618 500 25 000 BTU Window Heat Cooling Unit www crosley com TM Customer Focused Quality Driven CAMHE18 CAMHE25B2 B2...

Page 2: ...e read this manual carefully and keep it for future reference TABLE OF CONTENTS Installation Instructions 12 4 11 Normal Sounds Important Safety Instructions 1 3 Troubleshooting 15 16 Air Conditioner...

Page 3: ...xcess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explos...

Page 4: ...ters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth...

Page 5: ...the windowis a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditionerhas been securely and correctly installed according to the ins...

Page 6: ...ton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use NOTE Preliminary Instructions Do the following before starting to...

Page 7: ...g 2 7 Remove shipping screws from top of unit and also on the side by the base if installed see Fig 5 8 Hold the cabinet while pulling on the base pan handle and carefully remove the unit 9 Add two fo...

Page 8: ...dow filler panel frame into channel in the top angle and bottom rail Do both sides 4 Insert washer head locking 7 16 screws 2 into holes in top leg of filler panel frame see step 6 Do not totally tigh...

Page 9: ...1 Carefully raise window to expose filler panel locking screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely Tighten locking screws on top Fig 17 3 Ins...

Page 10: ...1 Lift air conditioner and carefully slide into cabinet leaving 6 inches protruding 2 DO NOT push on controls or finned coils 3 Be sure chassis is firmly seated towards rear of cabinet 4 Installation...

Page 11: ...lide the R1 insulation panel into the side curtain the side with pattern should facing the indoor side Fig 22 INSTALL WEATHER STRIPPING only be applicable to Energy star models 11 11 In order to minim...

Page 12: ...e provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 does not support major structural loads such as the frame construction at ends of windows and und...

Page 13: ...binet wooden frame using shims if frame is oversized to eliminate distortion See Fig 8 Remember to maintain proper slop as described in Step 3 Fig 8 OPTIONAL Caulking and installation of trim on inter...

Page 14: ...make noise because of poor wall or window construction or incorrect installation UNIT CONTROL TO TURN UNIT ON OR OFF Press ON OFFbutton toturn unito n or off NOTE The uni t wi ll ini tia te automatic...

Page 15: ...elected temperature This ends the Sleep modeand the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep bu...

Page 16: ...r and possible circuit breaker tripping The fan will continue to run during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to t...

Page 17: ...ed Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem A...

Page 18: ...ing Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty...

Page 19: ...alls etc 13 Damages caused by services performed by unauthorized service companies use of parts other than genuine Crosley parts or parts obtained from persons other than authorized service companies...

Page 20: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Reviews: