Crosley CAMHE12A2 User Manual Download Page 6

5

INSTALLATION  INSTRUCTIONS

Location Requirements:

IMPORTANT:Observe all governing codes and ordinances. Check the location where air conditioner
will be installed.Proper installation is your responsibility. Make sure you have everything necessary 
for correct installation.
    Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner.
    Free movement of air in room to be cooled.
    A large enough opening for the air conditioner.
    Adequate wall support for weight of air conditioner. Air conditioner weights between 70 and 85 Ibs
    (32 to 40 kgs).

Do not use an extension cord.
Cabinet louvers must not be obstructed. Air must
be able to pass freely through the cabinet louvers.
(FIG.1)

FIG.2

FIG.1

A. Cabinet louvers

Remove and dispose of / recycle packaging materials. Remove tape and glue residue from surfaces 
before installing the air conditioner. Rub a small amount of liquid dish soap over the adhesive with 
your fingers. Wipe with warm water and dry.
Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove
 tape or glue. These products can damage the surface of your air conditioner.
Handle the air conditioner gently.
1. Remove the air conditioner from the carton and place it on cardboard.
2. Remove 1 shipping screw from each side of the cabinet (FIG.3).
3. Remove front panel by removing 1 Phillips screw from each side of the front panel. Set screws a
    side and save (FIG.4).
4. Pull on the handles to slide the air conditioner out of the cabinet. Place the air conditioner on 
    cardboard (FIG.5).

NOTE:

Installation parts are supplied for double-hung windows up to 36  (91.4 cm) wide. A special Wide 
Window Kit is available from your dealer or service center. See Accessories  .
Do not use any screws other than those specified here.

Installation parts are supplied for double-hung windows up to 36  (91.4 cm) wide. A special Wide 
Window Kit is available from your dealer or service center. See  Accessories .
Do not use any screws other than those specified here.

  

Remove packaging material:

NOTE:

NOTE:

Window Installation:

Window opening measurements (FIG.2) :
    26-7/8   to 36   (68.3 cm to 91.4 cm) opening width.
    16-1/2   (41.9 cm) minimum opening height.

Summary of Contents for CAMHE12A2

Page 1: ... it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual c...

Page 2: ...excess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric shock It may...

Page 3: ...lters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure Hold the plug by the head of the power plug when taking it out Turn off the main power switch w...

Page 4: ... the windowis a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditionerhas been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner be careful to avoid cuts from sharp metal fins on ...

Page 5: ...the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here TOOLS NEEDED Flat blade and Phillips screwdrivers Tape measure Level Drill and 3 16 1 8 3 32 or smaller drill bit Through the wall Installation In addition to the tools listed above the following tools are needed for through the wall installation TOOLS NEEDED Saw Caulk 1 2...

Page 6: ...sharp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Handle the air conditioner gently 1 Remove the air conditioner from the carton and place it on cardboard 2 Remove 1 shipping screw from each side of the cabinet FIG 3 3 Remove front panel by removing 1 Phillips screw from each side of the fron...

Page 7: ...e the top channel on top of the air conditioner cabinet lining up the three holes in the top channel with the three holes on top of the air conditioner cabinet 3 Using three pan head Phillips thread cutting screws attach the top channel to the air conditioner cabinet A B B Top channel FIG 6 O thread cutting screws NOTE FIG 7B Top view A B FIG 7A A B FIG 7C A A Side Curtain A Curtain housing B Curt...

Page 8: ...t to drill one hole through the hole in the middle of top rail and into the window frame Attach cabinet to window with one 10 x 3 4 or 1 2 round head Phillips screw FIG 11 Place two safety locks into the holes that located in the bottom of the cabinet and drive two locking screws through the safety locks into the cabinet as shown FIG 12 1 1 3 Check that air conditioner cabinet is tilted back about...

Page 9: ...front of panel with front panel screws FIG 17 8 Plug into a grounded 3 prong outlet 9 Press RESET on the power supply cord Through the Wall Cabinet Installation Option 1 wood metal or plastic molding When using a wood metal or plastic molding the wood frame should line up with the inside wall as shown FIG 18 Option 2 Plastered wall with no molding If the plastered wall is to be flush with the cabi...

Page 10: ...un to the outside The cabinet should slop at least half a bubble towards the rear 4 Reuse the insulation to seal opening between cabinet and frame 5 Use existing holes in sides and top of cabinet and seven 10 X 1 wood screws not provided to attach cabinet to frame 6 Caulk all outside wall openings around cabinet Do not overtighten screws or the cabinet will distort and provide a poor air seal betw...

Page 11: ... will be automatically maintained O O O O anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature see To Operate on Fan Only section Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan High Pitched Chatter High efficiency compressors may have a high pitched chatter during the cooling cycle Gurgle Hi...

Page 12: ...selected temperature This ends the Sleep modeand the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again Press Check filter button to initiate theis feature This feature is a reminder to clean the Air Filter for more efficient operation The LED light will illumi nate after 250 hours of operat...

Page 13: ...n during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Left and Right Temp Timer buttons at the same time for 3 seconds 12 Air Directional Louvers Air Direction 4 way The 4 way air directional louvers allow you to direct the air flow Up or Down on some models and Left or Right throughout the r...

Page 14: ... of defective workman ship or materials in this appliance Solution Air conditioner does not start Wall plug disconnected Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem Air from unit does not feel cold enough Set to a Lower temperature O O Room tempera...

Page 15: ...ling Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty air filter air restricted Clean air filter Air movement sound This is normal If too loud set to a slower FAN setting Outside temperature extremely hot Set FAN speed to a Higher setting to bring air p...

Page 16: ...CW012IU J1B1A XD XBT 202000192631 20140108 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Reviews: