Your air conditioner needs annual maintenance to help
ensure steady, top performance throughout the year.
Call your local authorized dealer to schedule an annual
checkup. The expense of an annual inspection is your
responsibility.
OR
If you are familiar with electrical appliances, you can do
the cleaning and maintenance yourself. If you choose to
do so, follow these steps:
NOTE: Do not lift, push, or pull on any expanded gray
polystyrene from inside the air conditioner.
1. Unplug air conditioner or disconnect power.
2. Remove the front panel (See “Cleaning the front

panel” on page 11.)

3. Remove green ground wire (A) from the base. Keep

ground screw.

4. Remove air conditioner from cabinet. Take care when

handling area with sharp metal fins.

5. Wrap the fan motor (B), connector plug (C), electrical

control box (D), and compressor terminals (E) in
plastic film and make sure no water or other liquid
gets inside any of these parts. It could damage the
insulation and cause serious mechanical problems.

6. Carefully clean and hose out the base (F), condenser

coil (G), evaporator coil (H), and condensate pan (I).
Clean at least once a year or more often if the con-
denser and evaporator coils and pan collect dirt,
sand, leaves, insects, or algae. Also, clean if you
detect an odor coming from the air conditioner.

7. Remove the plastic film from the motor and electrical

parts.

Electrical Shock Hazard

Disconnect power before doing any maintenance.

Do not drink water collected by the air conditioner.

Failure to follow these instructions can result in
death, electrical shock, or sickness.

Excessive Weight Hazard

Use two or more people to move and install 
air conditioner.

Failure to do so can result in back or other injury.

8. Replace air conditioner into cabinet and reattach

green ground wire and front panel.

NOTE: It is a good idea to wait 24 hours before starting
the air conditioner again. This allows time for all areas
to dry out.
9. Plug in air conditioner or reconnect power.

Electrical Shock Hazard

Connect green ground wire to ground screw.

Failure to do so can result in death or electrical
shock.

WARNING

WARNING

Performing Annual Maintenance

EN

B

C

G

B

C

D

E

F

D

H

F

G

H

I

E

I

WARNING

A

Summary of Contents for CA18WC00

Page 1: ...del aire 3 Tablilla de direcci n de aire 4 Panel de control 5 Filtro deslizable Use and Care Guide Manual de Uso y Cuidado 1182935 Rev A 2000 All rights reserved 2000 Todos los derechos reservados RO...

Page 2: ...need to know your complete model number and serial number You can find this information on the model and serial number label See Installation Instructions for model and serial number location Please...

Page 3: ...injury or sickness when using your air conditioner follow these basic precautions Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Unpl...

Page 4: ...por personas capacitadas para operarla debidamente D a la unidad el mantenimiento debido Quite tambi n la Etiqueta de Energ a Utilice un pa o h medo para eliminar cualquier resto de goma NO use instr...

Page 5: ...some models or HIGH COOL the fan circulates air continuously HIGH COOL for maximum cooling MED COOL some models for normal cooling LOW COOL for sleeping comfort FAN ONLY When the FAN ONLY setting is...

Page 6: ...rature is 45 F 7 C or above the air conditioner operates as a heat pump and heats the air running through the unit When the outside temperature is below 45 F 7 C the unit switches to an electric resis...

Page 7: ...lls you when the filter needs to be cleaned When the amount of dirt on the filter reaches a level that would affect cooling performance a red flag appears under the words FILTER MONITOR on the control...

Page 8: ...temperaturas LOW COOL Poco fr a MED COOL Medio fr a en algunos modelos o HIGH COOL Muy fr a el ventilador hace circular el aire continuamente HIGH COOL para enfriamiento m ximo MED COOL en algunos mod...

Page 9: ...a calentar gire el Control de THERMOSTAT en la direcci n contraria a las manecillas del reloj Para modelos con bomba de calor Cuando la temperatura exterior es de 7 C 45 F o m s el acondicionador de a...

Page 10: ...ladores aspiradores cuando est cocinando lavando la ropa o ba ndose Gotas de agua que caen sobre el condensador produciendo tintineos o chasquidos Las gotas de agua ayudan a enfriar el condensador El...

Page 11: ...for best cooling or heating and operating efficiency Check the filter every 2 weeks to see if it needs cleaning Do not operate the air conditioner without the filter in place 1 Unplug air conditioner...

Page 12: ...arato caliente y enfr e m s eficientemente Revise el filtro cada dos semanas para ver si necesita limpieza No haga funcionar el acondicionador de aire si el filtro no est colocado en su lugar 1 Desenc...

Page 13: ...ms 6 Carefully clean and hose out the base F condenser coil G evaporator coil H and condensate pan I Clean at least once a year or more often if the con denser and evaporator coils and pan collect dir...

Page 14: ...serpent n del condensador G el serpent n del evaporador H y el colector de condensado I Haga esta limpieza por lo menos una vez al a o o con m s frecuencia si los serpentines del condensador y del ev...

Page 15: ...circuit Replace with a 15 amp time delay fuse or circuit breaker of the correct capacity See Electrical requirements in the Installation Instructions for the correct capacity Do not use an extension...

Page 16: ...iple rooms Heating units are supplemental only See page 6 Clean the filter See page 11 Clean the inside evaporator and outside condenser coils See page 13 Use a fan to exhaust heat or moisture from th...

Page 17: ...mo circuito Reempl celo con un fusible de retardo de 15 amperes o un disyuntor con la capacidad correcta Verifique la capacidad correcta en la secci n de Requisitos el ctricos Requisitos el ctricos de...

Page 18: ...e el filtro Ver p gina 12 Limpie el evaporador interno y los serpentines del condensador externo Ver p gina 14 Use un ventilador para eliminar el calor o la humedad de la habitaci n Trate de no usar a...

Page 19: ...uientes accesorios para su acondicionador de aire en la tienda de aparatos electro dom sticos de su localidad Filtros de aire de reemplazo Un filtro de aire limpio y de buena calidad es importante par...

Page 20: ...ributors Our service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the authorized service company in your area you...

Page 21: ...en su localidad Nuestros t cnicos en servicio est n capacitados para satisfacer la garant a del producto y proporcionar servicios posteriores a la garant a en cualquier parte de los Estados Unidos Pa...

Reviews: