In case using a wire rope diameter different to the calibrated one, torque it until the rope is in contact with
BOLT body and use a torque wrench to measure the torque value.
After calibration make sure the BOLT is tightened to the same torque value.
It is recommended to perform periodic checks on the BOLT including visual inspection and making sure the
bolts are torqued correctly.
NOTE: Care to be taken not to drop the sheave or bolts while working at a height
Wire Rope Diameters
Wire rope diameter (mm)
Torque setting (Nm)
32
26
16
30
20
10
06
Wir
e R
ope Diamet
ers
v1.00
Part No:
SU6674