13
Cromtech Generator
Operation & Instruction Manual
•
Clean fuel strainer.
EVERY 500 HOURS
•
Replace spark plug and cleaner element.
•
Clean and adjust carburettor, valve clearance and valve seat along with
cylinder head.
EVERY 1000 HOURS
(24 MTHS)
•
Inspect control panel parts.
•
Check rotor and starter.
•
Replace engine mount rubber.
•
Overhaul engine.
•
Change fuel lines.
NOTE: (*)
Initial oil change should be performed after first 20 hours of use. Thereafter, change oil as
per the engine’s instructions manual.
PERIODIC OPERATION AND INSPECTION
When generator is used as an emergency electrical power source, periodic operation and inspection is
required to ensure generator will operate when needed.
Fuel and engine oil will deteriorate overtime, and this may cause the engine to be difficult to start and
will result in improper engine operation and fault.
�
�
�
CAUTION
Since the fuel will have deteriorated overtime, replace with fresh fuel periodically, every (3) months is
recommended.
STEP 1
Check the fuel, engine oil and air cleaner.
STEP 2
Check there are no leaks from the engine oil and /or fuel.
STEP 3
Start engine and check it runs smoothly and has a stable power output.
STEP 4
Apply a power load of approximately ¾ of generator continuous output capacity and allow to run
for approximately 10-15 minutes.
12.
TRANSPORTATION AND STORAGE
TRANSPORTATION
When transporting the generator, make sure that the fuel is drained from the tank.
�
�
�
CAUTION
•
To prevent fuel spillage due to vibration and impact,
NEVER
transport the generator with a full fuel
tank.
•
ENSURE
the fuel tank cap is securely fitted and tight.
•
NEVER
allow the generator to be exposed to direct sunlight or at high temperatures as this may
cause expansion of the fuel tank and a potential danger of fire or explosion.
•
KEEP
the fuel in a separate storage tank when transporting.
STEP 1
Turn the engine switch to the “STOP” position.
STEP 2
Drain the fuel from the tank.
STEP 3
Secure the tank cap.