TYPE OF WATER 

If any liquid contains stringy or large material that may cause obstruction, in which case, a 
suction strainer should be used. If the pump is needed for chemicals, you must check the 
pump compatibility with your local dealer. 

FIXED INSTALLATIONS 

 

In some installations and only if the pump is used under stressful conditions, such as 
pumping uphill for long distances, the pump may not work on start up. 

To rectify this, a check valve should be installed between the pump and the pipe and a 
gate valve should be installed on the pump discharge. If it still fails, open the valve to 
release a full flow of water and close it again. It should now pump fully. Under some 
conditions the procedure might have to be repeated at each start up. 

STORAGE 

 

Make sure that the engine is completely cooled off before storage. 

 

Clean up oil and dust accumulation on rubber parts. 

 

Drain pump completely of all water. 

 

Cover the machine and store it in a dry place. 

 

For long-term storage of petrol unit, remove fuel from the fuel tank. Also remove fuel 
remaining in the fuel line and chamber of the carburettor. To drain fuel from the 
chamber of the carburettor, remove the drain plug provided at the chamber and 
remove fuel.

 

 

WARRANTY 

Consult the Crommelins Machinery Warranty Information leaflet, supplied with your new 
product, for full details of your machinery warranty including consumer advice and 
information about accessing a service agent to repair your product. You can also visit our 
website at www.crommelins.com.au to find your local service agent who will be able to 
assist with all warranty claims.  

 

Summary of Contents for FT150HP

Page 1: ...allation checking and maintenance We highly recommend that you retain this manual for ready reference regarding its proper handling OPERATION INSTRUCTION MANUAL Head Office 08 9350 5588 Customer Servi...

Page 2: ...at you can refer to it at anytime Due to constant efforts to improve our products certain procedures and specifications are subject to change without notice When ordering spare parts please have handy...

Page 3: ...g the machine in a closed room tunnel or other poorly ventilated places as the exhaust fumes contain deadly poisonous carbon monoxide If the machine is unavoidably operated in such a place discharge t...

Page 4: ...te intervals N B Do not run the pump dry of water for extended periods as it will destroy the mechanical seal and void warranty HOW THE PUMP OPERATES Before starting the pump make sure the non return...

Page 5: ...ure might have to be repeated at each start up STORAGE Make sure that the engine is completely cooled off before storage Clean up oil and dust accumulation on rubber parts Drain pump completely of all...

Page 6: ...ium Suction Type Self priming Self priming Self priming Self priming Impeller Twin Twin Twin Twin Axle Seal Material Ceramic carbon Ceramic carbon Ceramic carbon Ceramic carbon Engine Make Robin Robin...

Page 7: ...uminium Aluminium Suction Type Self Priming Self Priming Self Priming Self Priming Impeller Twin Twin Twin Twin Axle Seal Material Ceramic carbon Ceramic carbon Ceramic carbon Ceramic carbon Engine Ma...

Page 8: ...anufacturers instruction manual Engine with low power 1 Throttle control lever not set to full throttle position 1 Set throttle control lever to full position Engine runs rough 1 Dirty air filter 2 Ou...

Page 9: ...Discharge Bend 1 36N Impeller Inner Rear 1 13 Discharge Tee Outlet 1 1 37F Diffuser Inner Rear 1 14 Rubber Gasket 1 37R Diffuser Outer Front 1 15 Butterfly Nut 1 1 38 Washer 5 16 12 16 Rubber Gasket 1...

Page 10: ...Assessment Sheets for all Crommelins Machinery products If you require one due to work site policies and procedures or for your own reference please go to www crommelins com au to locate your product...

Page 11: ...11 NOTES...

Page 12: ...12 CROMMELINS FIRE FIGHTING PUMPS SINGLE IMPELLER OPERATION INSTRUCTION MANUAL Head Office 08 9350 5588 Customer Service 1300 554 524 Sales 1300 650 659 email crommelins com au...

Reviews: