15
Crommelins Generator Operation & Instruction Manual
Fuel and engine oil will deteriorate overtime, and this may cause the engine to be difficult to start and
will result in improper engine operation and fault.
CAUTION
Since the fuel will have deteriorated overtime, replace with fresh fuel periodically, every (3) months is
recommended.
STEP 1
Check the fuel, engine oil and air cleaner.
STEP 2
Check there are no leaks from the engine oil and /or fuel.
STEP 3
Start engine and check it runs smoothly and has a stable power output.
STEP 4
Apply a power load of approximately ¾ of generator continuous output capacity and allow to run
for approximately 10-15 minutes.
13.
TRANSPORTATION AND STORAGE
13.1
TRANSPORTATION
When transporting the generator, make sure that the fuel is drained from the tank.
CAUTION
•
To prevent fuel spillage due to vibration and impact,
NEVER
transport the generator with a full fuel
tank.
•
ENSURE
the fuel tank cap is securely fitted and tight.
•
NEVER
allow the generator to be exposed to direct sunlight or at high temperatures as this may
cause expansion of the fuel tank and a potential danger of fire or explosion.
•
KEEP
the fuel in a separate storage tank when transporting.
STEP 1
Turn the engine switch to the “STOP” position.
STEP 2
Drain the fuel from the tank.
STEP 3
Secure the tank cap.
CAUTION
•
DO NOT
place any heavy objects on the generator.
•
ENSURE
the generator is positioned on a flat surface and secured safety in the transport vehicle.
13.2
STORAGE
The following procedures should be followed prior to storage of your generator for periods of 6 months
or longer:
•
Drain fuel from fuel tank carefully by disconnecting the fuel line. Fuel left in the fuel tank will
eventually deteriorate making engine starting difficult.
•
PETROL ONLY
- Remove the carburettor float chamber and drain the carburettor.
•
Change engine oil.
•
Check for loose bolts and screws, tighten them if necessary.
•
Clean generator thoroughly with oiled cloth. Spray with preservative if available. (NEVER USE WATER
TO CLEAN GENERATOR).
•
Pull starter handle until resistance is felt, leaving handle in that position.
•
Store generator in a well ventilated, low humidity area.