CRL Unica hydraulic hinge 100E10

For more information Freephone UK and Ireland on 00 800 0421 6144  |  Fax free on 00 800 0262 3299 

Enter the door, possibly sloping for easier insertion. 

Then place the notch in the hinge seat.

Slide the cover on the hinge body.

Act on the four lower grains to adjust the alignment of the door (± 30mm with a 

1000mm reach). Once aligned block the screws

Use the gasket supplied to compensate for different thicknesses of 

glass (1) and tighten the 4 screws with (Ch3) key (2). See table.

Secure the covers by unscrewing the eight screws on 

the body.

Cover with screw-cover plates.

FUNCTIONING RANGE

Area wich is

controlled from the 

hydraulic system

Area of closing speed adjustment

Area wich is

controlled from the 

hydraulic system

Area wich is not controlled

from the hydraulic system

STARTING RANGE

STARTING RANGE

Area wich is not controlled

from the hydraulic system

For Glass
SIDE OF GLASS BLOCKING PLATE
1 gasket 0,5mm

BODY’S SIDE 
1 shaped gasket 

For Glass
SIDE OF GLASS BLOCKING PLATE
1 gasket 0,5mm + 1 gasket 1mm

BODY’S SIDE  

1 shaped 1 gasket 1mm

For Glass
SIDE OF GLASS BLOCKING PLATE
1 gasket 0,5mm

BODY’S SIDE 

1 shaped 2 gasket 1mm

Installation and adjustment instructions

CRL Patch Fitting Hydraulic Door Hinge

Adjust the final click strength with (Ch3) key acting on the 
nozzle denoted by the letter “S” with the door open to 45 
degrees. Turn clockwise to decrease the force and 
counter-clockwise to increase it.

Adjust  the  closing  speed  with  (Ch3)  key  acting  on  the 
nozzle denoted by the letter “V” with the door open to 45 
degrees. Turn  clockwise  to  reduce  speed  and 
counterclockwise to increase it. 