ABSOLUTE MAXIMUM RATINGS
If Military/Aerospace specified cards are
required, please contact the Critical Link
Sales Office or unit Distributors for
availability and specifications.
Maximum Supply Voltage
13.2 V
Storage Temperature Range
0 to 80C
OPERATING CONDITIONS
Ambient Temperature
Range
0 to 70C
Humidity
0 to 95%
Non-condensing
ELECTRICAL CHARACTERISTICS
Symbol
Parameter
Conditions
Typical
Limit
Units
(Limits)
Maximum Power Supply Output
I
Max
12V Supply (AC Adapter)
1
all components
1.2
A
I
Max
5.0V Supply
2
for external components
1.0
A
I
Max
3.3V Supply
2
for external components
1.0
A
Power Dissipation
V
S
Supply Voltage
12±5%
V
I
S
Supply Current
3
330
1
mA
Notes:
1. An alternative higher amperage AC/DC 12V adapter is available upon request. Contact Critical Link for
details and ordering information.
2. The maximum current supplied to external components should be limited to the specified maximum for
both the 5.0V and 3.3V supplies.