SOLO3DEE
30015978
10
Introduction
The SOLO sinewave inverters have been
designed to meet industrial and domestic needs.
They satisfy the highest demands of comfort,
safety and reliability.
Any device designed for the public electrical
network of 230V / 50 Hz can be connected to
them.
The SOLO inverters are the perfect solution as
sources of tension in any place where the public
network is not available.
Read the connection instructions thoroughly and
give them to the technician who is to install the
inverter so as to prevent any malfunction. Thus
you will have a modern and reliable installation
which meets requirements.
Should you have any doubt or question, do not
hesitate to contact your specialist salesperson
who will give you the best advice.
Important notes
A deficient assembly could damage the device,
cause function failures or potential damage to the
users.
The working device generates a high tension
which might be fatal in case of contact. So, any
manipulation of the inverter must be carried out
with utmost care. The following points must be
strictly observed :
The installation of the "SOLO" can only be
performed by a qualified technician.
In case of malfunction, only a technician specially
designated and trained by CRISTEC is allowed to
repair the device.
Warning :
Opening the inverters or using them
incorrectly will result in the immediate
loss of the warranty.
No current or tension generating devices (public
network, generator, ...) may be connected to the
output of the inverter because this could result in
its destruction.
As for the usage of batteries, follow the
manufacturer’s instructions
.
Important :
After disconnecting the battery, the output
tension (230V) may still remain for 30
seconds.
The ventilation of the device should never be
obstructed. Should the device be installed in an
enclosed structure, make sure that ventilation is
possible and adequate.
The installation and assembly of the device must
follow the rules stipulated.
This document is an essential part of the inverter
and must always be carried with it and be at the
disposition of anyone working on the installation.
Applications and Performances
As well as its modern design and its technical
characteristics, the SOLO inverter is also easy
and economical to use in almost all applications.
All devices working within the public electrical
network (230V - 50Hz) may be used with the
inverter (up to its nominal power).
The inverter generates a perfectly sinusoid output
tension, precisely adjusted by a high technology
regulation system.
Thus, the output tension is totally independent of
the charge and the fluctuation of tension in the
battery.
All inverters in the SOLO series are protected
against overloading and short circuits.
Due to obvious safety reasons, the inverter is not
automatically reactivated after a failure (overload,
short circuit,…).
Summary of Contents for SOLO 24V 2300W