background image

 

 

SOLO3DEE 

30015978 

 

 

 

10 

Introduction 

The SOLO sinewave inverters have been 
designed to meet industrial and domestic needs. 
They satisfy the highest demands of comfort, 
safety and reliability.  
 
Any device designed for the public electrical 
network of 230V / 50 Hz can be connected to 
them. 
 
The SOLO inverters are the perfect solution as 
sources of tension in any place where the public 
network is not available. 
 
Read the connection instructions thoroughly and 
give them to the technician who is to install the 
inverter so as to prevent any malfunction. Thus 
you will have a modern and reliable installation 
which meets requirements. 
 
Should you have any doubt or question, do not 
hesitate to contact your specialist salesperson 
who will give you the best advice. 

Important notes 

A deficient assembly could damage the device, 
cause function failures or potential damage to the 
users.  
 
The working device generates a high tension 
which might be fatal in case of contact. So, any 
manipulation of the inverter must be carried out 
with utmost care. The following points must be 
strictly observed : 
 
The installation of the "SOLO" can only be 
performed by a qualified technician. 
 
In case of malfunction, only a technician specially 
designated and trained by CRISTEC is allowed to 
repair the device.  

Warning : 

Opening the inverters or using them 

incorrectly will result in the immediate 

loss of the warranty. 

No current or tension generating devices (public 
network, generator, ...) may be connected  to the 
output of the inverter because this could result in 
its destruction. 
 
As for the usage of batteries, follow the 
manufacturer’s instructions

Important : 

After disconnecting the battery, the output 

tension (230V) may still remain for 30 

seconds. 

The ventilation of the device should never be 
obstructed. Should the device be installed in an 
enclosed structure, make sure that ventilation is 
possible and adequate. 
 
The installation and assembly of the device must 
follow the rules stipulated. 
 
This document is an essential part of the inverter 
and must always be carried with it and be at the 
disposition of anyone working on the installation. 

Applications and Performances 

As well as its modern design and its technical 
characteristics, the SOLO inverter is also easy 
and economical to use in almost all applications. 
 
All devices working within the public electrical 
network (230V - 50Hz) may be used with the 
inverter (up to its nominal power).  
 
The inverter generates a perfectly sinusoid output 
tension, precisely adjusted by a high technology 
regulation system. 
 
Thus, the output tension is totally independent of 
the charge and the fluctuation of tension in the 
battery. 
 
All inverters in the SOLO series are protected 
against overloading and short circuits. 
 
Due to obvious safety reasons, the inverter is not 
automatically reactivated after a failure (overload, 
short circuit,…). 

Summary of Contents for SOLO 24V 2300W

Page 1: ...ation et de montage User s and Installer s Handbook S A S CRISTEC 31 rue Marcel Paul Z I Kerdroniou est 29 000 QUIMPER FRANCE T l 33 0 2 98 53 80 82 Fax 33 0 2 98 55 64 94 e mail info cristec fr site...

Page 2: ...N 4 RACCORDEMENT 4 UTILISATION 4 COMMANDE A DISTANCE 5 R GLAGES 5 Standby Level 1 5 Proc dure de r glage 5 SURVEILLANCE 5 INDICATEURS 5 Run LED verte 3 5 Fault LED rouge 2 5 S CURIT 6 FUSIBLES INTERNE...

Page 3: ...SOLO entra ne la perte imm diate de la garantie Aucun appareil g n rateur de courant ou de tension ne doit tre connect la sortie de l onduleur car il peut entra ner la destruction de celui ci r seau...

Page 4: ...tempestif ult rieur Contr ler la tension et la polarit de la batterie La tension de la batterie doit correspondre celle pr vue par la fiche technique de l onduleur Raccordement de la batterie Cette co...

Page 5: ...ter Tourner sans appuyer dans le sens anti horaire jusqu ce que l onduleur s enclenche LED verte allum e V rifier que l onduleur retourne en mode stand by quelques secondes apr s d clenchement de tout...

Page 6: ...Veuillez vous en informer aupr s des organismes comp tents Exclusion de la responsabilit La pose la mise en fonction l utilisation la maintenance et le service ne peuvent pas faire l objet d une surve...

Page 7: ...s batteries Longueur des c bles max 2 m Utiliser des batteries adapt es la puissance de l onduleur Cbatt Ah 5 x Pnom Unom Cette valeur peut tre divis e par trois pour des applications de courte dur e...

Page 8: ...stal control D tection de la charge standby R glable 0 3 20 W Puissance maximale 15 min 1 3 1 6 x Pnom 25 C Puissance maximale 3 min 1 6 2 x Pnom 25 C Puissance cr te 5s 3 5 x Pnom Charge asym trique...

Page 9: ...TING 11 CONNECTION 11 USE 11 REMOTE CONTROL 12 ADJUSTMENTS 12 Standby Level 1 12 Adjustment procedure 12 CONTROL 12 INDICATORS 12 Green Run LED 3 12 Red Fault LED 2 12 SAFETY 13 INTERNAL FUSES 13 MAIN...

Page 10: ...hem incorrectly will result in the immediate loss of the warranty No current or tension generating devices public network generator may be connected to the output of the inverter because this could re...

Page 11: ...ontact Check the tension and polarity of the battery The tension of the battery should coincide with that mentioned in the technical characteristics of the inverter Battery connection This connection...

Page 12: ...anti clockwise without pressing until the inverter activates green LED illuminated Check that the inverter goes back to standby mode a couple of seconds after deactivation of all charges Warning In m...

Page 13: ...will find complete information about this in the relevant institutions Limitation of liability CRISTEC cannot control the installation use and maintenance of the inverter Thus we are not responsible...

Page 14: ...LED Fault indicator red LED Standby level adjustment Not avalable with Twinpower option Check battery polarity Max cables lenth 2 m Battery size sould be ajusted to the inverter s power Cbatt Ah 5 x...

Page 15: ...01 Crystal control Charge detection standby Adjustable 0 3 20 W Maximum power 15 min 1 3 1 6 x Pnom 25 C Maximum power 3 min 1 6 2 x Pnom 25 C Peak power 5s 3 5 x Pnom Asymmetric load Up to 2 x Pnom...

Page 16: ...SOLO3DEE 30015978 16...

Reviews: