CPS3-1M-2M-DED
19
Access to the user interface area:
2.3. USER INTERFACE AREA
Refer to appendix 1 or 2 according to model.
3. INSTALLATION
This paragraph deals with installation-related arrangements.
Installation and initial commissioning should be carried out by an electrician or professional installer in
accordance with the standards currently in force (for pleasure boats the applicable international standard is
ISO13297).
The installer should familiarize himselfwith this operating manual and inform users ofthe instructions for use and
the safety warnings set out in the manual.
The charger is fixed by 4 M5 round screws (diameter ofthe screw < 10mm in order to allow the opening ofthe
cover).
Fixing distance: see the corresponding drawing in chapter charger charger overall dimensions.
3.1. CHARGER OVERALL DIMENSIONS
Refer to appendix 3,4 or 5 according to model.
3.2. WIRING
3.2.1. Cable lead-in
The mains cable lead-in is routed through a cable gland.
The battery cable lead-in is routed through cable bushings (possibility to mount cable glands in place; not supplied
: see paragraph accessories).
The "accessory" cable lead-in (see paragraph accessories) is routed through 3 slots located over the cable
bushings.
When connecting or disconnecting a cable, the charger's power supply must be offand the batteries electrically
insulated from the charger.
The references for additional supplies required for the appliance to operate efficiently are provided in the
following paragraphs: failure to comply with these provisions renders the warranty null and void.