3.1

 

Normal use 

The fall prevention safeguard may only be used for the purpose for which it is intended. 

It must not be used for purposes other than its intended use, and its use is further 

subject to proper assembly, installation, operation, maintenance and repair. 

 

 

3.2

 

Abnormal use 

Abnormal use of the fall protection device is not allowed, including examples (not 

exhaustive) to be aware of. 

 

One must avoid: 

 

overloading the fall prevention safeguard by more persons than allowed using it 

 

load the pile with loads other than the accidental load of the person 

 

use the fall prevention safeguard for other than normal purposes 

 

 

3.3

 

Errors / Troubleshooting 

All technical faults are recorded in a logbook with description, date and name. 

 

 

Service / repair / maintenance 

To ensure optimum durability and reliability, the fall arrest post must undergo 

continuous inspection and maintenance. 

 

In case of malfunction or abnormal wear, this must be repaired immediately. 

 

4.1

 

Maintenance of fall protection equipment 

Maintenance of fall protection and inspection of fall protection equipment is a necessary 

safety measure when working at height. The equipment must be checked before use and 

it is therefore necessary to have a safe routine implemented in the daily workflow.  

 

It is therefore important that employees are aware of fall protection maintenance. 

 

However, it is the employer's duty to provide procedures for storage, maintenance, 

repair and replacement of equipment. As described in EN 365, fall protection equipment 

must undergo an annual inspection by an authorized or competent person. In addition, 

any equipment that has been subjected to maximum loads or is in questionable 

condition - must be discarded as it is no longer deemed to provide adequate safety. 

Summary of Contents for MONTAGE 21834.000

Page 1: ...User Manual Fall Protection Post CRH Concrete A S Vestergade 25 DK 4130 Viby S Doc ref Date sign 20 3172 rev 5 January 2021 ENI Worldwide Patent Pending...

Page 2: ......

Page 3: ...e 4 1 5 Technical data 5 2 Description of fall protection post 6 2 1 Structure 7 2 2 Operation Work instruction during setup 10 2 3 Signage 11 3 General instruction 11 3 1 Normal use 12 3 2 Abnormal u...

Page 4: ...nly one person shall be anchored to each anchorage point eye at the top of the pile It is important that the concrete deck is securely fixed or has a self weight so that it is not possible to tip rota...

Page 5: ...plied DS EN 12100 1 2011 Safety of machinery General principles for design Part 2 Safety of machinery Risk assessment and risk mitigation DS CEN TS 16415 Personal fall protection equipment Anchor devi...

Page 6: ...d base Fall protection post Type 21834 000 Series No 001 Maximum load 2 persons Production year 2021 Own weight 23 kg Always read the user manual before use EN 795 and DS CEN TS 16145 Data plate alumi...

Page 7: ...e 25 4130 Viby T 45 7010 3510 www crhconcrete dk page 5 1 5 Technical data Ambient environment Outdoor use 20 C to 60 C Material Stainless steel and aluminum Surface treatment None Weight total Approx...

Page 8: ...30 Viby T 45 7010 3510 www crhconcrete dk page 6 2 Description of fall protection post The fall protection post is CE marked according to DS EN 795 and DS CEN TS 16415 The data plate is located on the...

Page 9: ...otection post must be used with the following parts 1 Concrete deck with cast in lifting anchor 2 Lifting eye for fixing between concrete deck anchor and base plate 3 Bottom plate with locking pin for...

Page 10: ...CRH Concrete A S Vestergade 25 4130 Viby T 45 7010 3510 www crhconcrete dk page 8 Ad 2 Lifting eye for fixing between concrete deck anchor and base plate...

Page 11: ...CRH Concrete A S Vestergade 25 4130 Viby T 45 7010 3510 www crhconcrete dk page 9 Ad 3 Bottom plate with locking pin for fall protection post Ad 4 Column for fall protection post...

Page 12: ...peration Work instruction during setup Important Max usable distance from concrete edge 5000mm 1 Harness attachment loops 2 Anchor post mounted so that red marking is covered 3 Base plate to be mounte...

Page 13: ...re special rules for the use of fall protection equipment which are described in AT Guidance 2 4 1 on falls from a height on construction sites and 2 4 2 on falls from a height when working on roofs T...

Page 14: ...ervice repair maintenance To ensure optimum durability and reliability the fall arrest post must undergo continuous inspection and maintenance In case of malfunction or abnormal wear this must be repa...

Page 15: ...must be discarded Service scheme Checkpoints Yearly by instructed personnel Visual inspection of all welds X Cracks or deformations of steel structure X Cracks or deformations of lock pin and spring s...

Reviews: