Installing the threaded rod
WDI Mortar set
injection cartridge
threaded rod
fi xing plate
WDI-M Assembly component
static mixer
extension tube 1m
Assemble the mortar set and place the injection cartridge
into the applicator gun.
Expel a 10 cm length of mortar or two full presses of the
gun until the mortar has an even grey colour. This material
must be discarded. Insert the extension tube to the bottom
of the drill-hole. Draw the applicator gun slowly back out
of the drill hole during the fi lling process allowing
the pressure of the mortar to determine the
exiting speed. Inject about 11 ml mortar in
each drill hole. Observe the processing
and curing periods in the table below.
Processing and curing periods
temperature [C°]
in the drill hole
maximum
processing
time
minimal curing
period (
*
)
+ 40° C
85 seconds
15 minutes
+ 35°C up to + 39°C
85 seconds
20 minutes
+ 30°C up to + 34°C
2 minutes
25 minutes
+ 20°C up to + 29°C
4 minutes
45 minutes
+ 10°C up to + 19°C
6 minutes
1:20 hours
+ 5°C up to + 9°C
12 minutes
2:00 hours
+ 0°C up to + 4°C
20 minutes
3:00 hours
- 4°C up to - 1°C
45 minutes
5:30 hours
- 5°C
1:30 hours
5:30 hours
(
*
) values apply for dry concrete in the support element.
By slowly turning the threaded rod, press the rod into the
drill-hole until it reaches the bottom.
The threaded rod must not be moved or subjected to load
before the curing period is over.
injecting the mortar
installing the threaded rod
Observe the curing period