CREVIS FnIO S Series NA-9171 Quick Manual Download Page 2

FieldBus Input/Output System 

 

Serial Network Adapter 

 PROFIBUS  Network Adapter 

 Digital Input / Output 

 Analog  Input / Output 

 Special Module 

Quick Guide 

FnIO S-series 

NA-9171 

1. NA-9171 Specification 

* Specifications and designs could be changed without advance Notice 

Class 2, adjacent to voltage rating (30Vmax.) 

ITEM 

SPECIFICATION 

ITEM 

SPECIFICATION 

Surrounding Air 

Temp./  

Ambient Temp. 

-20

~55

 / -40

~85

 

Network Type 

ModBus-RS232 

Relative Humidity 

5% ~ 90% without condensation 

Cable 

Serial Twist cable 

Durable-

vib./impact 

IEC68-2-6(2G) / 10G 

Cable Length(m) 

15m 

Operating Mode 

Polling 

EMC/ESD 

EN50082 / EN50081 

Comm. Sp(Kbps) 

1.2k ~ 115.2kbps 

Mount Position 

On the left of FnIO-S series 

Expansion No. 

Max. 32 module 

Atmosphere 

Not so dusty without corrosive gas 

Max. node 

1 node 

Field Supp.Volt. 

Class 2,  24VDC 

24VDC (11VDC ~ 28.8VDC)

‏ 

Max. Digital I/O 

Input : 2016point / Output : 2016point 

Field Supp. Cur. 

Max. 10A 

Max. Analog I/O 

Input : 126Ch / Output : 126Ch 

FnBus Sup. Cur 

Max. 1.5A@5Vdc 

Max. Byte size 

Input : 252Bytes / Output : 252Bytes 

Isolation 

System power to internal logic : Non-isolation 

System power to I/O driver : Isolation 

Node No. Setting 

Rotary Switch 2ea(x10, x1) 

Size 

45mm 

×

 99mm 

×

 70mm 

Power Dissipation 

70mA typical @24Vdc 

Weight 

150g 

Certification 

UL / cUL / CE /FCC / RoHS (EU, China) 

RS232 

Cautions for your Safety 

Do not assemble the products and wire with power applied to the system. Else it may cause an electric arc, which can result into unexpected 
and potentially dangerous action by field devices. Arching is explosion risk in hazardous locations. Be sure that the area is non-hazardous or 
remove system power appropriately before assembling or wiring the modules. 

Do not touch any terminal blocks or IO modules when system is running. Else it may cause the unit to an electric shock or malfunction. 

Keep away from the strange metallic materials not related to the unit and wiring works should be controlled by the electric expert engineer. 
Else it may cause the unit to a fire, electric shock or malfunction. 

If you don’t follow the directions, it could cause a personal injury, damage to the equipment or explosion 

If you disobey the instructions, there may be possibility of personal injury, damage to equipment or  
explosion. Please follow below Instructions. 

   Check the rated voltage and terminal array before wiring. Avoid the circumstances over 55

 of temperature. Avoid placing it directly in the  

      sunlight.  

   Avoid the place under circumstances over 85% of humidity.  

   Do not place Modules near by the inflammable material. Else it may cause a fire. 

   Do not permit any vibration approaching it directly.  

   Go through module specification carefully, ensure inputs, output connections are made with the specifications. Use standard cables for wiring.  

   Use Product under pollution degree 2 environment. 

Before using the unit                                                                        

*We appreciate you for purchasing CREVIS Products. To use the units more effectively, please read this quick guide and refer to 
the respective user manual for further details. 

Warning

Caution! 

* Power Isolators must be used according to the usage of 5VDC/24VDC/48VDC or AC Voltage modules 

Summary of Contents for FnIO S Series NA-9171

Page 1: ...사고 오동작의 원인이 됩니다 화재 감전사고 오동작의 원인이 됩니다 화재 감전사고 오동작의 원인이 됩니다 화재 감전사고 오동작의 원인이 됩니다 화재의 원인이 됩니다 화재 및 감전의 원인이 됩니다 화재 및 감전사고의 원인이 됩니다 감전 화재 오동작 또는 제품 열화의 원인이 됩니다 화재 오동작 또는 고장의 원인이 됩니다 Update date 2013 1 30 구분 일반사양 구분 상세사양 사용 보존 온도 20 55 40 85 Network 방식 ModBus RS232 사용 보존습도 5 90 단 이슬이 맺히지 않을 것 Cable Serial Twist cable 내진동 내충격 IEC68 2 6 2G 10G Cable 길이 m 15m EMC ESD EN50082 EN50081 통신속도 Kbps 1 2k 115 2kbp...

Page 2: ...angerous action by field devices Arching is explosion risk in hazardous locations Be sure that the area is non hazardous or remove system power appropriately before assembling or wiring the modules Do not touch any terminal blocks or IO modules when system is running Else it may cause the unit to an electric shock or malfunction Keep away from the strange metallic materials not related to the unit...

Page 3: ...s OFF ON OFF 9600 bps ON ON OFF 19200 bps OFF OFF ON 38400 bps ON OFF ON 57600 bps OFF ON ON 115200 bps ON ON ON Watchdog Disable Watchdog OFF Enable Watchdog ON Byte Format 8 bit No Party 1 Stop OFF OFF OFF 8 bit Even Party 1 Stop ON OFF OFF 8 bit Odd Party 1 Stop OFF ON OFF 8 bit No Party 2 Stop ON ON OFF 7 bit No Party 2 Stop OFF OFF ON 7 bit Even Party 1 Stop ON OFF ON 7 bit Odd Party 1 Stop O...

Page 4: ...ame Adapter Slave received correct frame which address to the slave or broadcast About 20msec flashing TXD Transmit Data LED Off Not Powered Device is idle or may not be powered Flashing Green Adapter transmit frame Adapter Slave transmit frame About 20msec flashing I O Expansion Module Status LED Off Not Powered No Expansion Module Device has no expansion module or may not be powered Flashing Gre...

Reviews: