Crestron ZUM-FLOOR-HUB Quick Start Manual Download Page 1

The Crestron® Zūm® Floor Hub enables centralized management and time
clock for Zūm wireless commercial lighting systems. The device provides a
web-based user interface for easy configuration, control, monitoring, and
scheduling. The time clock feature enables automation of room lighting
and sensing behavior. The Zūm Floor Hub supports up to 1,000 individual
rooms equipped with Zūm lighting systems. The device also enables
integration with other Crestron lighting systems, control systems, touch
screens, shading, HVAC, and more.

In the Box

1

ZUM-FLOOR-HUB, Zūm® Floor Hub

Additional Items

1

Connector, 4-Pin (2003576)

1

Power Pack, 24 VDC, 2.5 A, 100-240 VAC (2045873)

2

Bracket, Rack Ear, 1U (2032122)

4

Foot, 0.5 in. x 0.5 in. x 0.23 in., Rubber, Black (2002389)

1

Power Cord, 5 ft 10 in. (1.78 m) (2042043)

Installation

The ZUM-FLOOR-HUB can be mounted into a rack or placed onto a flat
surface.

Mounting Into a Rack

The ZUM-FLOOR-HUB occupies 1U of rack space.

To install the included rack ears:

1. Use a #1 or #2 Phillips screwdriver to remove the three screws from
each side of the front of the device as shown in the following illustration.

2. Use the screwdriver and the screws removed in the previous step to
attach the included rack ears to the device.

3. Mount the device into the rack using four mounting screws
(not included).

1

ZUM-FLOOR-HUB

Zūm® Floor Hub

Summary of Contents for ZUM-FLOOR-HUB

Page 1: ... Additional Items 1 Connector 4 Pin 2003576 1 Power Pack 24 VDC 2 5 A 100 240 VAC 2045873 2 Bracket Rack Ear 1U 2032122 4 Foot 0 5 in x 0 5 in x 0 23 in Rubber Black 2002389 1 Power Cord 5 ft 10 in 1 78 m 2042043 Installation The ZUM FLOOR HUB can be mounted into a rack or placed onto a flat surface Mounting Into a Rack The ZUM FLOOR HUB occupies 1U of rack space To install the included rack ears ...

Page 2: ... ground building steel l The ZUM FLOOR HUB can be powered by the 4 position terminal block connector labeled NET or with the included 24 VDC power pack Connect the Control Subnet The ZUM FLOOR HUB has a dedicated Control Subnet that is used for communication between the control system and Crestron Ethernet devices This subnet allows for dedicated communication between the control system and Crestr...

Page 3: ...FL and the last 8 digits of the MAC address e g ZUM FL 7F8764BF The New User Registration screen is displayed during the first connection Enter the Username Password Firstname Lastname and Email Address and then tap Submit The ZUM FLOOR HUB settings page opens next as shown below For further configuration refer to the ZUM FLOOR HUB Supplemental Guide Doc 8355A 3 ZUM FLOOR HUB Zūm Floor Hub ...

Page 4: ...te at www crestron com legal software_license_agreement The product warranty can be found at www crestron com warranty The specific patents that cover Crestron products are listed at www crestron com legal patents Certain Crestron products contain open source software For specific information visit www crestron com opensource Crestron the Crestron logo 3 Series Cresnet and Zūm are either trademark...