background image

Crestron 

WPR-48 

Waterproof Wireless Handheld Remote

 

PRO2 System View 

 

The 

System Views

 

lower pane displays the PRO2 system tree. This tree can be 

expanded to display and configure the communications ports.

 

Expanded PRO2 System Tree 

 

C2Net-Device Slot in Configuration Manager 

An RF gateway device is required to incorporate a wireless RF transmitter into a 
Cresnet system. Once a gateway is configured in a C2Net-Device Slot, the slot 
allows Cresnet communication between the transmitter and the control system. 
Similarly, an IR gateway device or receiver is required to incorporate a wireless IR 
transmitter into a Cresnet system. 

To incorporate the RF configuration of the WPR-48 in a SIMPL program, in 
Configuration Manager, drag the CNRFGWA RF gateway from the Wireless 
Receivers | Wireless Receivers (RF) folder of the 

Device Library

. The 

System Views

 

upper pane displays the CNRFGWA device icon below the PRO2 graphic. The 
PRO2 system tree displays the CNRFGWA gateway in Slot 9, with a default Net ID 
of 24. 

NOTE:

  The ST-CP control processor is automatically configured with a 

CNRFGWA in its STCP-Net Device Slot 3, with a fixed Net ID of 2, when the  
ST-CP is dragged into the upper pane of 

System Views

. This Net ID cannot be 

changed. 

To incorporate the IR configuration of the WPR-48 in a SIMPL program, in 
Configuration Manager, drag the CNX-RMC or CNX-RMCLV room solution box 
from the Cresnet Control Modules | Cresnet Video Modules folder of the 

Device 

Library.

 The 

System Views

 upper pane displays the CNX-RMC device icon below 

the PRO2 graphic. Then drag the CNXRMIRD IR detector from the Wireless 
Receivers | Wireless Receivers (IR) folder of the

 Device Library

 and drop it on the 

CNX-RMC

The PRO2 system tree displays the CNXRMIRD IR detector in Slot 2 

of the CNX-RMC. 

Double-click the CNRFGWA or the CNX-RMC icon in the lower pane to open the 
“Device Settings” window, which displays device information. Select the 

Net ID

 tab 

to change the gateway Net ID. The window for the CNRFGWA is shown in the 
following figure.  

Operations Guide – DOC. 6254A 

Waterproof Wireless Handheld Remote: WPR-48  

  15 

Summary of Contents for WPR-48

Page 1: ...Crestron WPR 48 Waterproof Wireless Handheld Remote Operations Guide...

Page 2: ...arranty WARNING After installing button labels as described in this Operations Guide tighten all eight screws that secure the rear cover to the button faceplate evenly just until the gasket is no long...

Page 3: ...intable Customized Button Labels 10 Installing Replacing Button Labels 12 Installing Alternate Foot 13 Programming the WPR 48 14 Earliest Version Software Requirements for the PC 14 Programming with S...

Page 4: ......

Page 5: ...ate use under any lighting conditions The WPR 48 can communicate via RF or IR with a number of gateways in a Crestron control system Cresnet system Since it is compatible with Crestron s CNRFGWA and C...

Page 6: ...evice controller 3 The latest versions can be obtained from the Downloads Software Updates section of the Crestron website www crestron com Refer to NOTE after last footnote 4 Crestron 2 Series contro...

Page 7: ...ximum duration of 30 minutes per IEC 60529 IPX7 standards Exceeding these limits may result in damage to the equipment possible personal injury and void the product warranty The unit is shipped with t...

Page 8: ...ndows program based on the application of the unit within the Cresnet system Indicators The only indicators on the hand held WPR 48 are the four LEDs on the face of the unit above the button function...

Page 9: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between...

Page 10: ...adapter Refer to the following illustration NOTE Check the SIMPL Windows gateway models prior to setting the RF ID or IR ID Some gateway models do not support ID 00 or FF NOTE If the battery in the W...

Page 11: ...ill function The settings are not transferred to the device until that instruction is given When the window is first opened it displays the values currently in the connected device If there is no devi...

Page 12: ...the RF configuration are RF Remote RF ID 10 433 MHz 27 Buttons 100 Backlight Brightness 10 second Backlight Timeout unchecked Allow key presses If you select Load From Device and the device contains...

Page 13: ...the configuration setup operation If you select the Save To File button the saved file can be used to upload directly to the remote via the Viewport File Transfer Update WPR 48 Firmware function This...

Page 14: ...n labels Also requires Crestron Database version 16 3 or later The help file included with the software package provides detailed instructions for selecting the buttons and entering the legends To des...

Page 15: ...or nine characters in wider fields An error message appears if you try to enter too many characters You can select any of the three fonts available from the drop down list Arial Crestron Transport or...

Page 16: ...arefully reassembled Perform the following procedures 1 Using a 1 Phillips screwdriver remove the eight cover screws securing the rear cover to the button faceplate and lift the rear cover from the as...

Page 17: ...the alternate blank foot supplied refer to the following illustration and perform the associated procedures 1 Using a 1 Phillips screwdriver remove the two pan head Phillips screws securing the lanya...

Page 18: ...1 Crestron Database version 16 2 3 or later Required by SIMPL Windows and Crestron Engraver Viewport version 3 99 01 or later For setting up the unit configuration Crestron Engraver version 2 2 Requir...

Page 19: ...lays the CNRFGWA gateway in Slot 9 with a default Net ID of 24 NOTE The ST CP control processor is automatically configured with a CNRFGWA in its STCP Net Device Slot 3 with a fixed Net ID of 2 when t...

Page 20: ...s Wireless Remotes IR folder of the Device Library and drop it on the CNXRMIRD symbol in System Views The CNXRMIRD then displays the WPR 48 with the transmitter s default RF IR ID 0F Pro2 System Tree...

Page 21: ...n four different modes All four modes are configurable using the Crestron Viewport 48 button mode In 48 button mode each of the top eight pushbuttons can trigger up to three functions depending on whe...

Page 22: ...programmers to installers from Crestron to dealers etc Even firmware upgrades are available from the Crestron website as new features are developed after product releases In those instances one has th...

Page 23: ...ntacts of the WPR DS During a firmware upload procedure the charging circuits are automatically disconnected Typical Connection Diagram when Uploading Firmware from the PC 1 Open the Crestron Viewport...

Page 24: ...has been performed 2 Press one of the buttons on the WPR 48 to activate the unit The backlight should come on NOTE Be aware that pressing a button to activate the unit automatically sends whatever co...

Page 25: ...y charge is low Place unit in docking station to recharge battery Intermittent response during RF transmission RF gateway is near large metal structure Verify that large amount of metal is not blockin...

Page 26: ...the online help section of the Crestron website www crestron com to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available fea...

Page 27: ...t lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of t...

Page 28: ...Crestron Electronics Inc Operations Guide DOC 6254A 15 Volvo Drive Rockleigh NJ 07647 10 04 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice...