For the TPS-CBL-3/6/9 cable/port signals, refer to the table below.
NET/VIDEO Plug Pin-Outs
PIN
DESIGNATION
DESCRIPTION
1
+24V
Power (Network)
2
GND
Ground (Network)
3
C+
Chrominance (Positive)
4
C-
Chrominance (Negative)
5
Y
Data (Network)
6
Z
Data (Network)
7
Y+
Luminance (Positive)/Composite
8
Y-
Luminance (Negative)/Composite
9
GND
Ground (Network)
10
+24V
Power (Network)
Cable Connections
NOTE:
If connecting the video from the TPS-4500IMC Interface
Module (or optional TPS-4500IMW) to the touchpanel, exceeding a cable
length 30-feet will significantly degrade the signal. To maintain high-
quality video,
DO NOT
daisy-chain cables, Crestron TPS-BLOCK
devices or fabricate cables longer than 30-feet. For further information
about TPS-BLOCK devices, consult an appropriate installation guide that
can be obtained from the Products page (PRODUCT MANUALS section,
hardware section) or Downloads page (MANUAL Library) of Crestron’s
website (www.crestron.com). New users are required to register to obtain
access to the FTP site.