quickstart guide
TPMC-3SM & TPMC-3SMD
www.crestron.com
888.273.7876
201.767.3400
Specifications subject to
change without notice.
TPMC-3SM & TPMC-3SMD
2.8” Touch Screens
The Crestron
®
TPMC-3SM and TPMC-3SMD touch screens install into a standard electrical box.
Both are supplied with screws for installation.
To prepare for mounting, insert a small slot head screwdriver into the hole at the bottom of the
touch screen, shown in the illustration below and gently separate the back of the unit.
1
Install the Touch Screen
QUICKSTART DOC. 7238B (2031721, Sheet 1 of 2) 04.13
1
Insertion Point for Separation of Back Panel
To mount the TPMC-3SM or TPMC-3SMD into an electrical box, use the following procedure:
1. Use the two included screws to attach the back panel to the electrical box, as shown in
the following illustration.
For U.S.-style installations, use the #06-32 x 1 1/2” screws (2031703).
For European-style installations, use the #4B x 3/4” screws (2019088).
Mount the TPMC-3SM or TPMC-3SMD into an Electrical Box (U.S.-Style Electrical Box Shown)
2. When making connections to the TPMC-3SM and TPMC-3SMD, use Crestron power supplies for
Crestron equipment.
Apply power after all connections have been made.
3. Carefully position the front of the touch screen over the back panel and gently snap it into place.
4. Insert one of the included #04-40 x 1/4” screws into the bottom of the unit to secure the touch screen,
as shown in the illustration below.
For standard applications, use the Phillips screw (2007160).
For secure applications, use the security type Torx screw (2025312).
Hardware Connections for the TPMC-3SM and TPMC-3SMD
Secure the TPMC-3SM and TPMC-3SMD
LAN PoE :
10 BASE - T / 100 BASE - TX
Ethernet to LAN
Screws (2)
For U.S.-style: #06-32 x 1 1/2” (2031703)
For European-style: #4B x 3/4” (2019088)
Electrical Box
Screw (1) #04-40 x 1/4”
Phillips (2007160) for standard applications
Security type Torx (2025312) for secure applications
Insert screwdriver to separate back of touch screen
NOTE:
The included cable mount ferrite bead, FBLB-7 (2032427)
should be placed on the LAN cable in the electrical box.