2-Series Integrated AV Control System
Crestron
MP2 & MP2E
System Monitor [v1.001 (0001)]
12-19-01 16:25:23 32MB RAM, 4MB FLASH
CS>
7. At the Toolbox prompt, type
erase
and press
Enter
. The following text
appears in Toobox.
CS>erase
->25%->50%->75%->100%
Done
CS>
NOTE:
There are two methods for loading firmware through System Monitor
(using
Alt+O
or using
Alt+U
). Because the first MP2 & MP2E firmware version
3.016 had special memory requirements, you must use the following
Alt+U
procedure when reverting to firmware version 3.016 from version 3.050 or when
upgrading from 3.016 to 3.050.
For versions 3.050 and later, skip to step 13 below.
8. The *.CSU file must be extracted from the *.CUZ file to load from the
firmware. Use WinZip to open the *.CUZ file and extract the *.CSU file.
9. At the CS> prompt, type
SYSTEM
and press
Enter
(you will see a series of capital “C”s appear in Toolbox).
10. Press
Alt+U
on the keyboard or from Toolbox, select
Communications | XModem Send…
11. Find and select the correct firmware file (.CSU not .CUZ) and click
Open
.
12.
Once “Completed Successfully” appears in Toolbox, type
quit
at the
Toolbox prompt and press
Enter
.
NOTE:
The steps for firmware versions prior to 3.050 are now complete. For
versions 3.050 and later, use the steps below.
13. Press
Alt+O
(not zero) on the keyboard to open the “Firmware” window,
then click
Browse
.
14. Find and select the correct firmware file (.CUZ or .zip) and click
Open
.
15. In the “Firmware” window, click
Send
. You will see a “Confirmation”
window asking if you’ve selected the right file. Click
Okay
and you’ll see
the “File Transfer” window.
16. When file transfer is completed, you’ll see a window asking you to re-
connect. Click
Okay
, then close the “Firmware” window and re-connect
using the normal Address Book entry.
Network Analyzer
To assist with troubleshooting, the unit contains Crestron’s patent-pending network
analyzer to continuously monitor the integrity of the Cresnet network for wiring
faults and marginal system performance or other network errors. For more
information on how to use the network analyzer, refer to the Crestron Toolbox help
file and use the index to search for “Network Analyzer”.
28
•
2-Series Integrated AV Control System: MP2 & MP2E
Operations Guide – DOC. 6175A