2
quickstart guide
HTT-B2EX-BATT
www.crestron.com
888.273.7876
201.767.3400
Specifications subject to
change without notice.
HTT-B2EX-BATT
For regulatory compliance information, refer to Doc. 7451.
QUICKSTART DOC. 7450D (2036667) 12.15
Battery-Powered infiNET EX
®
2-Button Wireless Keypad
5
Firmware
It is recommended to have direct access to the HTT-B2EX-BATT and
to use Crestron Toolbox to set the RF ID of the device. Set the RF ID
for the HTT-B2EX-BATT by following these steps:
1. Wake the device by pressing the large or small button on the
HTT-B2EX-BATT.
2. Set the RF ID of the device using Crestron Toolbox. The RF ID
must match the RF ID specified in the Crestron Studio™ or SIMPL
Windows program.
3. Press the large or small button on the HTT-B2EX-BATT four times
(tap-tap-tap-tap) to ensure that the device is awake and the RF ID
is transferred to the device.
4
RF ID
WARNING
: Refer to the following warnings before changing the
batteries.
• Do not ingest batteries: chemical burn hazard.
• This product contains coin cell batteries. If a coin cell battery is
swallowed, it can cause severe internal burns in just 2 hours and
can lead to death.
• Keep new and used batteries away from children. If the battery
compartment does not close securely, stop using the product
and keep it away from children.
• If you think batteries have been swallowed or placed inside any
part of the body, seek immediate medical attention.
CAUTION
: The battery used in this device may present a risk of fire or
chemical burn if mistreated. Do not recharge, disassemble, heat above
212°F (100°C), or incinerate. Replace batteries with Panasonic
®
CR2450 only. Use of another battery may present a risk of fire or
explosion.
Follow the instructions below to replace the batteries in the
HTT-B2EX-BATT:
1. Using a Phillips head screwdriver, remove the two screws that
secure the base to the bottom of the device.
2. Gently separate the base from the device.
6
Replace Batteries
The product warranty can be found at www.crestron.com/warranty.
The specific patents that cover Crestron products are listed at patents.crestron.com.
Certain Crestron products contain open source software. For specific information, please visit
www.crestron.com/opensource.
Crestron, the Crestron logo, Crestron Studio, Crestron Toolbox, and infiNET EX are either trademarks or
registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Panasonic is
either a trademark or registered trademark of Panasonic, Inc. in the United States and/or other countries.
Other trademarks, registered trademarks, and trade names may be used in this document to refer to either
the entities claiming the marks and names or their products. Crestron disclaims proprietary interest in the
marks and names of others. Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2015 Crestron Electronics, Inc.
!
!
NOTE
: Before using the HTT-B2EX-BATT, ensure that the device is
using the latest firmware. Check for the latest firmware for the
HTT-B2EX-BATT at www.crestron.com/firmware. Firmware is loaded
onto the device using Crestron Toolbox.
To upgrade the firmware on the HTT-B2EX-BATT, follow the
procedure below using Crestron Toolbox (v. 2.36.216 or later):
1. Select
Tools
|
Network Device Tree View
.
2. Right-click the gateway in the
Network Device Tree View
window.
3. Select
Functions
|
Firmware Upload (Deep Sleep)
.
4. Click the
Load Firmware File
button in the
Firmware Upload
(Deep Sleep)
window and browse for the firmware in the
Open
window.
5. Once the firmware is selected, click
Open
to add the firmware to
Firmware Images
.
6. In the
Assignments
section, click the device (
CTRL
+ click or
SHIFT
+ click for multiple devices) that the firmware should be
assigned to. The row turns light gray.
NOTE
: If a device is not located in the
Assignments
section,
click
Show all Available IDs
.
NOTE
: If a deep sleep device has not been acquired by the
gateway, assign the firmware to an ID if the future ID number of
the device is known.
Screws
Tether
(Optional)
Batteries
Base
Device
3. Remove the two batteries from the HTT-B2EX-BATT, and replace
with two new Panasonic CR2450 batteries.
4. Reassemble the HTT-B2EX-BATT, and place it in its original
location.
NOTE
: Dispose of the used batteries promptly. Keep the batteries
away from children. Do not disassemble the batteries, and do not
dispose of them in fire.
7. In the
Firmware Images
section, click the firmware that should be
assigned to the device(s). The row turns light gray.
8. Once the device(s) and firmware are selected, click
Assign Selected
Image to Selected Target(s)
to assign the firmware to the device(s).
The firmware is stored on the gateway and assigned to the device(s).
9. Select a method to initiate the firmware upgrade on the device:
• Allow the HTT-B2EX-BATT to automatically initiate the firmware
upgrade, which occurs every 8 hours.
• To manually initiate the firmware upgrade, press the large or small