Crestron GLX-DIM6 Installation Manual Download Page 9

CRESTRON GREEN LIGHT™ 

Architectural Dimming 

Connector Wiring 

RED

WHITE

BLUE

BLACK

RED

WHITE

BLUE

BLACK

OVERRIDE:

FROM OTHER CABINET; 

FROM ALARM, ETC. 

(OPTIONAL); TO OTHER 

CABINET(S) IF NECESSARY

POWER:

24 VDC JUMPERED FROM NET 

PORT or EXTERNAL SUPPLY.  
PROVIDES CRESNET POWER 

TO THE MODULES

NET:

TO CONTROL SYSTEM AND 

OTHER CRESNET DEVICES

MODULES:

TO GLX MODULES

 

NET Port Wiring 

When wiring the supplied 

NET

 connectors for connection to a Crestron control system or other device on the 

Cresnet network, use Crestron certified wire such as CRESNET-NP or CRESNET-P.  

To ensure optimum performance over the full range of your installation topology, use Crestron certified wire. 
Failure to do so may incur additional charges if support is required to identify performance deficiencies because 
of using improper wire. 

When daisy-chaining connections between 

NET

 ports, strip the ends of the wires carefully to avoid nicking the 

conductors. Twist together the ends of the wires that share a pin on the network connector, insert the connection 
into the Cresnet connector, and tighten the retaining screw. Repeat the procedure for the other three conductors. 

POWER Port Wiring 

Low voltage (24 VDC) power must be supplied to the modules either internally via devices connected to the 

NET

 port or externally via a Cresnet power supply connected to the 

POWER

 port.  

To power the modules internally from line power, install a jumper from the 

INT

 pin on the supplied 

POWER

 

connector to the 

EXT

 pin on the 

POWER

 connector as shown in the following diagram. 

Providing Cresnet Power Internally  

 

When a lighting module is powered from line power, the module’s 

PWR

 LED will illuminate. 

Installation Guide – DOC. 6688A 

CRESTRON GREEN LIGHT Architectural Dimming  

  9  

 

Summary of Contents for GLX-DIM6

Page 1: ...binet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc E227280 cabinet and E103692 modules Application The following diagram shows CRESTRON GREEN LIG...

Page 2: ...5 8 270 mm 10 3 16 259 mm 10 1 16 256 mm W3 H2 KNOCKOUTS 4 TOTAL FOR 3 4 19 mm CONDUIT TYPICAL BOTH SIDES 21 1 2 547 mm 21 1 2 547 mm 21 1 2 547 mm 21 1 2 547 mm DIMENSION GLE 2X2 GLE 3X2 GLE 2X4 GLE...

Page 3: ...1 14 7 8 378 mm 18 1 4 464 mm 14 7 8 378 mm 14 7 8 378 mm 11 11 16 297 mm 15 1 16 383 mm 11 11 16 297 mm 11 11 16 297 mm W1 8 3 16 208 mm 8 3 16 208 mm 6 13 16 174 mm 6 13 16 174 mm 8 204 mm 8 204 mm...

Page 4: ...equate clearance in front of the cover for servicing The cabinet is designed for surface mounting on a wall Cabinets are intended for indoor use only The ambient temperature range should be 32 F to 10...

Page 5: ...d to the branch circuit breakers The following must be performed after installation Connect incoming feed conductors to the breaker panel section A of the following diagram Connect load wiring to GLX...

Page 6: ...OR MAX WIRE RANGE TORQUE Max Current Neutral and Main Lugs 10 2 0 AWG CU or 6 2 0 AWG AL 6 300 kcmil CU or AL 15 lb ft 20 3 Nm 21 lb ft 28 5 Nm 6 350 kcmil CU or AL 1 0 750 kcmil CU or AL 275 300 lb i...

Page 7: ...M CONTROL GLX DIMFLV8 only 28 12 AWG 4 43 lb in 0 5 Nm 5 16 8 mm GROUND BAR 14 10 AWG 35 lb in 4 0 Nm 5 16 8 mm GROUND LUG 14 4 AWG 45 25 lb in 5 1 2 8 Nm 3 4 19 mm 1 Each output has a label with the...

Page 8: ...ll jumpers 4 Turn on the circuit breakers Control Wiring Section C The bottom of the cabinet contains Cresnet connections for interfacing to the rest of the Crestron control system It also provides an...

Page 9: ...ciencies because of using improper wire When daisy chaining connections between NET ports strip the ends of the wires carefully to avoid nicking the conductors Twist together the ends of the wires tha...

Page 10: ...ause the breaker trips the module will automatically draw power from the 24VDC supply if available In this case the PWR LED will flash OVERRIDE Port Wiring Low voltage input devices such as the Crestr...

Page 11: ...state is shown on the NET ID display On for on for two seconds after the button is released Press the T button to turn the output off The corresponding ON LED extinguishes and the output state is show...

Page 12: ...lp file To save the state of all of the outputs as an override setting press and hold the OVR button for three seconds The OVR LED blinks to indicate the new override settings have been stored System...

Page 13: ...nals present at bottom of the cabinet Determine the reason for the short Remove or remedy the short e g GLS PLS 120 277 phase loss sensor may not have been installed properly or actual phase loss has...

Page 14: ...t can be changed from the front panel of each module The Net IDs of each module in the system must be unique To set the Net ID using the front panel 1 Press the recessed SETUP button to enter the Setu...

Page 15: ...scent ballast HID motor Dimmable Loads 0 10 VDC dimmable fluorescent ballasts i e Advance Mark 7 or other ballasts that comply with the specifications for control by DC voltage in ANSI C82 11 2002 and...

Page 16: ...ays batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regardi...

Reviews: