quickstart guide
MP-FS100 PAK
www.crestron.com
888.273.7876
201.767.3400
Specifications subject to change
without notice.
MP-FS100 PAK
For details, refer to the latest version of the
MP-FS-RX1/RX2
Operations Guide, Doc. 7164.
QUICKSTART DOC. 7161B (2030815) 0
8
.11
FreeSpeech
®
Single-Channel Wireless Mic System
2
During the following procedures, refer to the above illustration and to the included
Microphone LED Code Reference Guide (Doc. 7165).
A. Pair Microphone with Receiver
1. Hold the MP-FSMIC
ON
button until the mic Status LED rapidly flashes green.
2. The mic will begin pairing with the receiver. Make sure the mic has line of sight to the
MP-FSIR. When pairing is complete, the Status LED will slowly blink green. Time to
pair is typically between five and ten seconds.
The mic must be turned off and turned on again to pair to another receiver.
B. Mute and Volume Adjustments
1. Press
the
MUTE
button to mute the mic (observe the blink pattern); press it again to
un-mute. When muted, the mic automatically turns off after two minutes.
2. When the mic is not muted, the
VOL
button can be used to adjust the mic volume.
3. When the mic is muted, the
VOL
button adjusts the line level audio volume.
4. Line volume is automatically “ducked” (reduced) when the user talks into the mic.
5. Hold
the
MUTE
button for five seconds to turn off the mic (turns off automatically if
muted for two minutes, or when placed in the charger.)
6. If the mic loses sight of the MP-FSIR for seven seconds, the mic will automatically
mute (turns off automatically if muted for two minutes).
7. If the RF link is lost for 10 seconds, the mic turns off.
C. Emergency
Trigger
Hold the
ALERT
button for eight seconds to generate two beeps from the speakers and
close the alert relay contacts until the button is released.
D. Receiver Controls - Default Settings
1.
BASS
and
TREBLE
: Typically, set these controls to their center detent positions.
Slightly reducing treble can help to reduce feedback.
2.
MASTER VOLUME
: With the control in its center detent position, have the instructor
speak from the most likely position in the room and adjust this control clockwise so
that the speakers just begin to exhibit feedback, and then reduce the setting by
turning counterclockwise.
BEACON SENSOR
:
From Up To Four
IR Beacon Sensors
(Two In Parallel Per
Input Connector)
MUTE SENSOR:
From Optional
MP-FS-PAS
PA Audio Sensor or
Contact Closure
ALERT OUT
:
To Building
Management Alert
System or Control
System Input
LINE IN
:
From Unbalanced
Line-Level Audio
Outputs
LINE OUT
:
To Unbalanced
Line-Level Audio
Inputs
SPEAKER OUT4/8
Ω
:
To Left and Right
Channel Speaker
Inputs
Ground
Basic Operation
6
Crestron, the Crestron logo, and FreeSpeech, are trademarks or registered trademarks of Crestron
Electronics, Inc. in the United States and other countries. Other trademarks, registered trademarks, and
trade names may be used in this document to refer to either the entities claiming the marks and names
or their products. Crestron disclaims any proprietary interest in the marks and names of others.
©2011 Crestron Electronics, Inc.
Ensure that the MP-FS-RX1 receiver is installed and connected as instructed on page 1,
that power is on (the green LED is on), that line level audio is supplied from a DVD
player, a laptop computer, or other device, and that the MP-FSMIC microphone has
been fully charged.
24VDC @ 2.0A:
From Power Pack
(Included)