Wall-Mount Wired Panel

R E M O T E    C O N T R O L   S Y S T E M S

2

DOC. 8002B

Specifications subject to change without notice.

Each unique panel or component on the CRESNET II network requires the setting of an identity code (ID CODE). ID CODES are
two-digit hexadecimal numbers, from 10 to FE. The ID CODE of the panel should be set to match the ID CODE specified in the
NET.ID statement of the CRESNET II SIMPL-C program referencing the panel (refer to  syntax section). To set an ID CODE,
remove the panel from the electrical box and disconnect power.

Accessible through the back plate are two miniature circuit-mounted rotary switches, identified as H and L. These 16-
position hexadecimal switches can be set to 0 through F. Using a small screwdriver, rotate the arrow in the center of the
switch marked H to point to the first (or most-significant) digit or letter of the specified ID CODE. Set the switch marked L to
the second (least-significant) digit or letter of the specified ID CODE.

The 4-pin connector marked NET should be wired to the CRESNET II network. Network termination points are available at
the control system power supply. Network units may also be daisy-chained together. Refer to the latest revision of the
CRESNET II reference manual section on CNPWS power supplies (Doc 8017 or Doc. 8091) for wire gauge specifications and
connection details.

The panel drawing on the previous page shows the location of the SIMPL-C button numbers and their corresponding button
positions. Buttons or bargraphs which are not used need not be assigned a signal name.

REQUIRES:

CRESNET II Workshop Version 4.00 or later.

CRESNET II Operating System SR30160.OPS or later.

FURTHER INQUIRIES:

If after reviewing this information you still have additional questions, please contact a CRESTRON technical support
representative by dialing (888) CRESTRON [(888) 273-7876] or (201) 894-0660.