DO
GUIDE
Wiring the LED Strip
DO
Join an infiNET EX
®
Network
The device connects to the Crestron network via the infiNET EX
®
communications protocol. Use
the procedures outlined below to join or leave an infiNET EX network and to verify communications
between the device and the control system.
Joining an infiNET EX Network
Before a device can be used in a lighting system, it must first join an infiNET EX network. To join an
infiNET EX network, the device must be acquired by an infiNET EX gateway.
NOTE
: A device can be acquired by only one gateway.
1. Put the infiNET EX gateway into Acquire mode from the unit itself or from Crestron Toolbox™
software. Refer to the gateway’s manual at www.crestron.com/manuals for details.
NOTE
: In an environment where multiple gateways are installed, only one gateway should be in
Acquire mode at any time.
2. Put the device into Acquire mode:
a. Tap the
SETUP
button three times, and then press and hold it down (tap-tap-tap-
press+hold) until the LED on the device blinks once (this can take up to 10 seconds).
b. Release the button to start the acquire process. The LED blinks slowly to show that the
device is actively scanning the infiNET EX network.
• The LED turns on for 5 seconds to show that the device has been successfully
acquired by the infiNET EX network.
• The LED blinks fast to indicate that the device was not successfully acquired by the
infiNET EX network. Tap the
SETUP
button to acknowledge the failure. Ensure the
gateway is in Acquire mode and within range before attempting the acquire process
again.
3. Once all devices have been acquired, take the gateway out of Acquire mode. Refer to the
gateway’s manual for details.
CLC-1LEDPWM-RGBW-EX
RGBW LED Controller
DO
Install the Device
The Crestron
®
CLC-1LEDPWM-RGBW-EX can be mounted onto any surface using three screws
(not included). For best results, position the device to avoid interference from nearby RF sources,
obstructions, and metal surfaces.
DO
Connect the Device
Make the necessary connections as called out in the illustrations that follow. Apply power after all
connections have been made.
NOTE
: When making connections to the CLC-1LEDPWM-RGBW-EX, use Crestron power supplies
for Crestron equipment.
Hardware Connections for the CLC-1LEDPWM-RGBW-EX
DO
Check the Box
QTY PRODUCT
PART NUM.
1
Connector, 2-Pin
2003574
1
Connector, 6-Pin
2003578
Power supply connection
To LED channels
+RGBW
+RGBW
+RGBW