Crestron CHV-RTHS Installation Manual Download Page 6

Remote Temperature/Humidity Sensors 

Crestron

 CHV-RTS/CHV-RTHS

 

Specifications 

SPECIFICATION DETAILS 

Temperature Range (CHV-
RTS and CHV-RTHS) 

-30º to 120ºF (-34.44Cº to 
48.89ºC)* 

Humidity Range (CHV-
RTHS only) 

0 to 100% 

 

*Thermostat front panel indoor temperature display is limited to a range 
of 0 – 110ºF (-18º to 43ºC). The front panel outdoor thermostat display 
will display the full range of temperature. 

Physical Description 

Refer to the illustrations below and on the following page. 

 

The face of the sensor is 1.5 in (3.81 cm) wide. The sensor body is 2.22 in 
(5.64 cm) long, and mounts nearly flush to the wall. 

 

The CHV-RTS and CHV-RTHS

 

remote sensors are contained in a 

cylindrical plastic body with a metal cap.  They mount in a one-inch 
diameter hole, exposing a 1.5 in (3.81 cm) diameter disk that protrudes 
approximately 1/8 in (0.32 cm) from the surface of the wall.  Total 
mounting depth is about 2.25 in (5.72 cm).  

 

Front and Angled Views 

1.59 in

(4.04 cm)

1.

50

 in

(3

.8

1 c

m

)

Mounting Clips

 

2  

  Remote Temperature/Humidity Sensors   

Installation Guide – DOC. 8189A 

Summary of Contents for CHV-RTHS

Page 1: ...Crestron CHV RTS CHV RTHS Remote Temperature Humidity Sensors Installation Guide ...

Page 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2004 Crestron Electronics Inc ...

Page 3: ...TS CHV RTHS 1 Introduction 1 Specifications 2 Physical Description 2 Industry Compliance 3 Installation 4 Hardware Hookup 5 Problem Solving 8 Further Inquiries 8 Future Updates 8 Return and Warranty Policies 9 Merchandise Returns Repair Service 9 CRESTRON Limited Warranty 9 Installation Guide DOC 8189A Contents i ...

Page 4: ......

Page 5: ...upports the addition of two optional remote sensors in any combination two temperature two temperature humidity or one of each Firmware release 2 0 supports the addition of up to four optional remote sensors in any combination for each thermostat Outdoor conditions can be imported from the optional external sensors CHV RTS or CHV RTHS temperature and temperature humidity respectively Functional Su...

Page 6: ...r to the illustrations below and on the following page The face of the sensor is 1 5 in 3 81 cm wide The sensor body is 2 22 in 5 64 cm long and mounts nearly flush to the wall The CHV RTS and CHV RTHS remote sensors are contained in a cylindrical plastic body with a metal cap They mount in a one inch diameter hole exposing a 1 5 in 3 81 cm diameter disk that protrudes approximately 1 8 in 0 32 cm...

Page 7: ...d to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling N11785 NOTE This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Install...

Page 8: ...the latest version of Crestron CHV TSTAT CHV THSTAT Thermostats Operation and Installation Guide Doc 8163 NOTE Crestron strongly recommends low capacitance twisted pair wire such as CAT3 up to 250 ft 76 2 m or CAT5 up to 500 ft 152 4 m network cable when using remote sensors Maximum distance from sensor to thermostat is 500 ft 152 4 m If multi conductor cables are used the leftover conductors must...

Page 9: ...on the rear plastic housing of the thermostat Separate the thermostat from its backplate The thermostat terminal blocks mate to pins protruding out of the front thermostat assembly Thermostat firmware release 1 x supports the addition of only two optional remote sensors temperature and or temperature humidity per thermostat on sensor inputs RS1 and RS2 Thermostat firmware release 2 x supports up t...

Page 10: ...24V Y Z G NETWORK Remote Sensor 1 Remote Sensor 2 Thermostat Backplate Connection Example 2 Connecting four temperature sensors CHV RTS to the thermostat maximum number of temperature sensors 1 Remote Sensor 1 and 3 are connected to RS1 and RSR 2 Remote Sensor 2 and 4 are connected to RS2 and RSR TOP HUM RHU RSR RSR RS1 RS2 24 C 24 R 24V Y Z G NETWORK Remote Temperature Sensor 1 Remote Temperature...

Page 11: ... 1 and 2 are connected to RS2 and RSR TOP HUM RHU RSR RSR RS1 RS2 24 C 24 R 24V Y Z G NETWORK Remote Temperature Humidity Sensor 1 Remote Temperature Sensor 1 Remote Temperature Sensor 2 Thermostat Backplate NOTE For additional firmware details refer to the latest version of the Crestron CHV TSTAT CHV THSTAT Thermostats Operations and Installation Guide Doc 8163 and CHV RSS Slab Sensor Installatio...

Page 12: ...America at 5255 5093 2160 In Australia and New Zealand call Crestron Control Solutions at 61 2 9737 8203 Future Updates As Crestron improves functions adds new features and extends the capabilities of this product additional information may be made available as manual updates These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical docu...

Page 13: ... incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if...

Page 14: ...Remote Temperature Humidity Sensors Crestron CHV RTS CHV RTHS 10 Remote Temperature Humidity Sensors Installation Guide DOC 8189A This page intentionally left blank ...

Page 15: ...Crestron CHV RTS CHV RTHS Remote Temperature Humidity Sensors This page intentionally left blank Installation Guide DOC 8189A Remote Temperature Humidity Sensors 11 ...

Page 16: ...Crestron Electronics Inc Installation Guide DOC 8189A 15 Volvo Drive Rockleigh NJ 07647 09 04 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Reviews: