Crestron CGEIB-IP Operations & Installation Manual Download Page 4

Summary of Contents for CGEIB-IP

Page 1: ...Crestron CGEIB IP KNXControlInterface Operations Installation Guide ...

Page 2: ...ufacture the Crestron CGEIB IP has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling Industry Compliance This Crestron CGEIB IP has been manufactured to comply with UL s Standards for Safety in Canada and the United States This product is Listed to appliccable UL Standards and requirements by Underwriters Laborator...

Page 3: ...Crestron CGEIB IP KNXControlInterface Operations Installation Guide All brand names product names and trademarks are the property of their respective owners 2009 Crestron Electronics Inc ...

Page 4: ......

Page 5: ...Crestron CGEIB IP KNXControlInterface Operations Installation Guide ...

Page 6: ...the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Disconnect power prior to connecting or disconnecting equipment Do not install in direct sunlight The apparatus must be installed in a way that the power cord can be removed either from the wall outlet or from the device itself in order to disconnect the mains power Prevent foreign objects from enterin...

Page 7: ...MPL Windows 13 Example Program 13 Uploading and Upgrading 14 Programs and Firmware 14 Operation 17 Main Module Crestron KNX IO v3 1 17 Group Modules 17 The different types of Data Type modules 17 Data type 1 bit 18 Data type 4 bit 18 Data type 1 Byte 18 Data type 2 Byte 19 Data type 4 Byte 19 Data type 14 Byte 20 Polling 20 Problem Solving 22 No Ethernet communication on CGEIB IP 22 Reference Docu...

Page 8: ......

Page 9: ... installation using either RS232 or Ethernet TCP IP Also the Crestron CGEIB IP filters the desired information out of received KNX messages and sends them to the Crestron control system via the same interface RS232 or TCP IP which provides the Crestron installation with live updates of the KNX installation Features and Functions Specifications Specifications for the Crestron CGEIB IP are listed in...

Page 10: ... footnotes 2 Crestron 2 Series control systems include the AV2 and PRO2 Consult the latest Crestron Product Catalog for a complete list of 2 Series control systems NOTE Crestron software and any files on the website are for authorized Crestron dealers and Crestron Authorized Independent Programmers CAIP only New users may be required to register to obtain access to certain areas of the site includ...

Page 11: ...h RS232 connected DTR High green with IP connected 3 Power LED Color blue Blue if operating voltage is applied 4 RS232 Connector DB9 female bidirectional RS232 port 5 RJ 45 Connector RJ 45 Socket 6 KNX BUS Connector Wago connector that connects the CGEIB IP with the KNX bus 7 Power Connector Wago connector used to power the CGEIB IP The CGEIB IP should be powered with 24V AC DC 8 KNX Programming L...

Page 12: ...y only after PowerOn or Reset i e if a network cable is plugged after PowerOn of the CGEIB IP the LAN port does not fetch an IP address over DHCP Thus the LAN port is not accessible in the network Best practice Before powering up the CGEIB IP all other connections should be made The CGEIB IP does not support POE Commissioning of the LAN port The LAN port must be connected to the network Afterwards...

Page 13: ...will show you all CGEIB IP s in your network and report their IP address and TCP port to communicate on The CGEIB IP only configures its Ethernet port upon start up SO after every change in the IP configuration DHCP or static make sure to reboot the CGEIB IP with the network cable plugged in NOTE As described above the Ethernet configuration only takes place when no RS 232 cable I connected Theref...

Page 14: ...Interface Crestron CGEIB IP Operations Installation Guide DOC 0009 Changing the IP address configuration Open browser e g Windows Internet Explorer Browse to the IP address of the LAN port Select menu item Network to setup basic IP configuration static or DHCP ...

Page 15: ...X EIB Control Interface Crestron CGEIB IP 7 Select menu item Serial Settings and make sure the baudrate is set to 57600 This is not the RS 232 baud rate the unit would use to communicaie serially It is in face the baudrate used internally to translate TCP IP communication to RS_232 ...

Page 16: ... EIB Control Interface Crestron CGEIB IP Operations Installation Guide DOC 0009 Select menu item Connection make sure Accept Incoming is set to Yes and verify the port used Select menu item Configurable pins and make sure the settings are as below ...

Page 17: ...ormat however are The installer uses the Group Addresses to define what functions can be controlled by the KNX installation For example every controllable light zone will have at least one By sending a value to this address the particular function will be triggered E g sending the value 0 to this address will result in the light switching off A group address list shows the Crestron programmer whic...

Page 18: ...ely you can import the ETS configuration in CSV format export file straight into the CGEIB IP It is also possible to transfer an old project in EGT format from a previous CGEIB IP configuration If you need more information to import ETS files please type F1 Functions Import and export file in the KNX Gate software for further information The list will be sent from the PC to the CGEIB IP over a dir...

Page 19: ...t loaded filter table from the CGEIB IP with the option Start reconstruction Set CGEIB IP communication parameters like Transmit for received data and Acknowledge for transmit Communication parameters Under Setup Gateway setup you can change the following options Transmit for received data on KNX The Crestron controller will automatically receive data from the KNX units when their values change Ex...

Page 20: ...the response speed to Crestron Switching of the limiter should only be done when possible after verification with the KNX installer Be aware that adjustments to checkboxes described above need to be uploaded with the address list to confirm the adjustment More information on these options can be found in the KNX software Note Minimal software requirements Microsoft NET Framework 2 0 or higher Free...

Page 21: ...nded software versions visit the Version Tracker page of the Crestron website www crestron com versiontracker Programming with SIMPL Windows SIMPL Windows is Crestron s premier software for programming Crestron control systems It is organized into two separate but equally important Managers Configuration Manager Configuration Manager is the view where programmers build a Crestron control system by...

Page 22: ...ograms and Firmware Program or firmware files may be distributed from programmers to installers or from Crestron to dealers Firmware upgrades are available from the Crestron website as new features are developed after product releases One has the option to upload the CGEIB IP firmware via the KNX Gate software RS 232 only SIMPL Windows If a SIMPL Windows program is provided it can be uploaded to t...

Page 23: ...Crestron CGEIB IP KNX Control Interface Operations Installation Guide DOC 0009 KNX EIB Control Interface Crestron CGEIB IP 15 3 Scan for the correct baudrate 4 Wait until a baudrate is found ...

Page 24: ...EIB Control Interface Crestron CGEIB IP Operations Installation Guide DOC 0009 5 Select Programming then firmware download and then Firmware version 7 and higher 6 Select firmware and click open The CGEIB IP will now be updated with the new firmware ...

Page 25: ...e that the modules are ready to be used The ConnectionStatus output provides feedback on the current status of the TCP IP connection with the CGEIB IP Other functionality includes polling the value for all associated KNX data type modules and enabling disabling debug mode Debug mode should be turned off during normal operation Group Modules Basically for every Group Address that needs to be contro...

Page 26: ... used to control dimmers The 4 bit module requires the usual address parameters Dimming speed is set standard to 1 although the KNX has 7 different dimming speeds Speed 1 slow is standard as this proved to be sufficient The feedback shows the dimming up and dimming down activity only not the light level The feedback is independent from the dimming speed Even when an KNX button panel controls the s...

Page 27: ...Byte modules are mostly used to read out analog values like temperature The module also offers inputs and outputs to use the EIS type EIS5 is a KNX data type that is commonly used to send a 2 Byte decimal value to the KNX system E g Set the Set_EIS5_Value input to 2550 to send 25 5 to the KNX system Values to set the correct temperature 1800d 2200d depend on the KNX device Data type 4 Byte The 4 b...

Page 28: ...em is that feedback signals are not always generated automatically for every change on the network E g a dimmer can have multiple group addresses via which it is controlled It can for example use 3 addresses One to switch on off 1 bit one to dim up down 4 bit and one to create a level feedback value absolute value 1byte With every action the light level can change so the momentary level feedback s...

Page 29: ...eedback of every used Group Address The answer is processed by the normal group modules and appears at the particular feedback output The Poll_All input should only be used at the start of the program to sync all KNX modules Use the Poll_Value inputs on the KNX Data Type modules to poll for individual values once the program is started Polling is only possible if you enable the Read flag in the ET...

Page 30: ...b interface can be used to set up the TCP IP communication with the CGEIB IP but does not allow you to set up the device with group addresses You d still need to use KNX Gate to set the group addresses via RS 232 Now there has been a wrong shipment of CGEIB IP s that included a beta version of our new Crestron friendly web interface You will not be able to connect to these CGEIB IP s via TCP IP We...

Page 31: ...ol Interface Crestron CGEIB IP 23 1 Please use the Deviceinstaller software to examine the Ethernet address of the CGEIB IP By default it is set up as DHCP so it should be assigned an address by the DHCP server automatically In Deviceinstaller select Device Search to autodiscover the CGEIB IP ...

Page 32: ...l Interface Crestron CGEIB IP Operations Installation Guide DOC 0009 2 Use your web browser to browse to this IP address In case your browser displays a web interface as the one below with a Crestron banner the web firmware of the CGEIB IP needs to be updated ...

Page 33: ...e the Lantronix Device Installer software Vesion 4 2 and select Device Search Select the CGEIB IP in the list on the left hand side highlight it and select Device Upgrade When asked for select the XPort03 ROM6507COB1602 lxi file and start the upgrade Please contact Crestron Technical Support for the XPort03 ROM6507COB1602 lxi file ...

Page 34: ...Control Interface Crestron CGEIB IP Operations Installation Guide DOC 0009 4 After a succesfull upgrade the web interface should be changed to the version below If you are prompted for username and password you can just leave these blank and press Enter ...

Page 35: ...IP KNX Control Interface Operations Installation Guide DOC 0009 KNX EIB Control Interface Crestron CGEIB IP 27 5 Refer to Changing the IP address configuration on page 6 of this manual to correctly set up you CGEIB IP ...

Page 36: ... Crestron s award winning customer service team by calling Crestron at 32 15 509920 You can also log onto the online help section of the Crestron website www crestron com onlinehelp to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features Future Updates As Crestron improves functions adds new features and extends t...

Page 37: ...ing but not limited to using the Software a either directly or through commands data or instructions from or to another computer b for local campus or wide area network internet or web hosting services or c pursuant to any rental sharing or service bureau arrangement The Software is designed as a software development and customization tool As such Crestron cannot and does not guarantee any results...

Page 38: ...antially in accordance with the published specifications for a period of ninety 90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limited warranty as stated in its accompanying written material Crestron shall at its option repair or replace or refund the license fee for any Software found defective by Crestron if notified by you within th...

Page 39: ...od of one 1 year touchscreen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warrant...

Page 40: ...KNX Control Interface Crestron CGEIB IP 32 KNX EIB Control Interface Crestron CGEIB IP Operations Installation Guide DOC 0009 ...

Page 41: ...Crestron CGEIB IP KNX Control Interface Operations Installation Guide DOC 0009 KNX EIB Control Interface Crestron CGEIB IP 33 ...