background image

Professional Multimedia Switch 

 

Crestron 

C2N-MMS

 

• 

(Optional) SystemBuilder version 2.0 or later with SystemBuilder 
Templates version 2.0.1or later. Requires the following software versions: 

SIMPL Windows version 2.06.20 or later with library update file 
345 or later. Requires SIMPL+ Cross Compiler version 1.1. 

Crestron database 17.2.2 or later 

Vision Tools Pro-e 3.3.4.0 or later 

Crestron Toolbox 1.01.06 or later 

Engraver 2.4.1.2 or later 

Microsoft DCOM '98 if running under Win 95 or 98 (not needed 
for NT or 2000) 

Microsoft Data Access Components if running under Win 95 or 98 
(not needed for NT or 2000) 

Programming with the Crestron SystemBuilder 

The easiest method of 
programming, but does not 
offer as much flexibility as 
SIMPL Windows.  

Crestron SystemBuilder offers automatic programming for such residential and 
commercial applications as audio distribution, home theater, video conferencing, and 
lighting. The interface of this tool guides you through a few basic steps for 
designating rooms and specifying the control system, touchpanels, devices, and 
functionality. Crestron SystemBuilder then programs the system, including all 
touchpanel projects and control system logic. 

Crestron SystemBuilder is fully integrated with Crestron's suite of software 
development tools, including SIMPL Windows, VT Pro-e, and the Crestron 
Database. Crestron SystemBuilder accesses these tools behind the scenes, enabling 
you to easily create robust systems.  

For additional details, download SystemBuilder from the Crestron website and 
examine the extensive help file. 

Programming with SIMPL Windows 

NOTE

: The following assumes that the reader has knowledge of SIMPL Windows. 

If not, refer to the extensive help information provided with the software.  

NOTE

: The following are acceptable file extensions for programs that include a 

C2N-MMS, developed for specific control system types: 
.smw:  

projectname

.smw (SIMPL Windows source file) 

.spz:  

projectname

.spz (compiled file for 2-series) 

.usp:  

projectname

.usp (source code module for SIMPL+) 

.umc:

  projectname

.umc (user macro for SIMPL) 

NOTE

: In the following description, the MP2E multimedia processor is used. 

SIMPL Windows is Crestron's software for programming Crestron control systems. 
It provides a well-designed graphical environment with a number of workspaces 
(i.e., windows) in which a programmer can select, configure, program, test, and 
monitor a Crestron control system. SIMPL Windows offers drag and drop 
functionality in a familiar Windows

®

 environment.  

16  

  Professional Multimedia Switch: C2N-MMS 

Operations Guide – DOC. 6374 

Summary of Contents for C2N-MMS

Page 1: ...Crestron C2N MMS Professional Multimedia Switch Operations Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...Programming Software 15 Earliest Version Software Requirements for the PC 15 Programming with the Crestron SystemBuilder 16 Programming with SIMPL Windows 16 Programming with VisionTools Pro e 18 Uplo...

Page 4: ......

Page 5: ...nput channels with Auto Detect supporting composite and Y C S video formats Two video output channels supporting composite and Y C S video formats Supports NTSC and PAL signal types Transient blanking...

Page 6: ...s Transient blanking disables the output signal before the sync is switched to another source Transient free switching between RGB sources is completed in less than 1 10 of a second The following diag...

Page 7: ...nverter installed RGB sources with resolutions up to 2048 x 1536 can be switched to either of the two video outputs in Y C S video or composite formats using National Television System Committee NTSC...

Page 8: ...ect on the Y input 75 0 3Vpp to 1 5Vpp with no offset at unity gain Max DC offset with min input 1 0V Max DC offset with max input 0 5V RGB Output Channels Type Output Level Impedance Sync Output Leve...

Page 9: ...ster to obtain access to certain areas of the site including the FTP site Physical Description The front panel of the C2N MMS contains a green PWR and yellow NET LED that illuminate when power is on a...

Page 10: ...EO IN and VIDEO OUT Each video input and output features two BNC connectors When switching an S video signal the chrominance C and Luminance COMP Y connectors should be connected When switching compos...

Page 11: ...e used for setting up the unit s network ID during the initial configuration of a Cresnet system or when the device is being added replaced Refer to Identity Code on page 9 for detailed information In...

Page 12: ...Insufficient power can lead to unpredictable results or damage to the equipment Please use the Crestron Power Calculator to help calculate how much power is needed for the system http www crestron com...

Page 13: ...tron control systems You can use the Crestron Toolbox to Observe system processes Upload operating systems and firmware Upload programs and touchpanel projects Set or change device Network IDs Change...

Page 14: ...r if you attempt to use an ID that is already in use by a device that is equipped with TSID Duplicate Net ID Warning Message This method does not change the Net ID as assigned in SIMPL Windows For inf...

Page 15: ...OSITE OR S VIDEO RGBHV OUTPUTS FREQUENCY AND LEVEL COMPENSATION C Y 1 C Y 2 3 Y C 1 Y C 2 Y C COMP COMP VIDEO IN COMP COMP VIDEO OUT COMP NET RGBHV IN 1 2 3 4 RGBHV OUT 24 1 Z Y G G 2 24 Z Y SETUP C R...

Page 16: ...MS is shipped from the factory with the DDC feature disabled NOTE The sync input impedance and DDC feature should be set prior to placing the C2N MMS in an equipment rack Finding the DIP Switches The...

Page 17: ...eatures switchable 3 dB frequency compensation and 1 25 dB signal boost to provide clear images on cable runs over 100 feet The following table illustrates which settings to use for specific RGB cable...

Page 18: ...ld be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips Two ears are provided with the C2N MMS so that t...

Page 19: ...a user wishes to create a touchpanel project using templates with a different look and feel this can be accomplished by making a custom template This custom template can then be used by SystemBuilder...

Page 20: ...ol system logic Crestron SystemBuilder is fully integrated with Crestron s suite of software development tools including SIMPL Windows VT Pro e and the Crestron Database Crestron SystemBuilder accesse...

Page 21: ...ews lower pane displays the MP2E system tree This tree can be expanded to display and configure the communications ports Expanded MP2E System Tree C2Net Device Slot in Configuration Manager To incorpo...

Page 22: ...in Programming Manager Programming Manager is where programmers program a Crestron control system by assigning signals to symbols The symbol can be viewed by double clicking on the icon or dragging it...

Page 23: ...following sections define how one would upload a SIMPL Windows program to the control system or upgrade the firmware of the C2N MMS However before attempting to upload or upgrade it is necessary to es...

Page 24: ...enabled Software handshaking XON XOFF not enabled Address Book Window Serial Setup 3 After setting the correct parameters click OK to return to the Crestron Toolbox main window 4 Click Tools Network...

Page 25: ...bles are used Refer to the control systems Operations Guide for information about RS 232 cables 2 With a serial connection verify that the correct COM port on the PC has been selected Some computers h...

Page 26: ...ls System Info 4 When the System Info window appears and you are connected to the control system the Functions option becomes available from the menu bar 5 Select Functions SIMPL Program The SIMPL Pro...

Page 27: ...es functions adds new features and extends the capabilities of its products firmware upgrades are posted To upgrade the firmware complete the following steps 1 Verify that the procedure for Establishi...

Page 28: ...te the firmware upg file Locate Firmware in the Open Window 7 Click Open and the file transfers to the unit File Transfer Window 8 The Firmware window reopens indicating the new firmware version Click...

Page 29: ...perly connected Verify that all cables are secure Further Inquiries If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award win...

Page 30: ...nt lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of...

Page 31: ...Crestron C2N MMS Professional Multimedia Switch Operations Guide DOC 6374 Professional Multimedia Switch C2N MMS 27 This page intentionally left blank This page intentionally left blank...

Page 32: ...Crestron Electronics Inc Operations Guide DOC 6374 15 Volvo Drive Rockleigh NJ 07647 2012952 Tel 888 CRESTRON 10 05 Fax 201 767 7576 Specifications subject to www crestron com change without notice...