“Identify Transmitter” Window
5. Point the universal remote at the C2N-IRGW-F and program the
remote with an RC5 code (some Sharp codes are acceptable as
well) as outlined in the manufacturer's manual.
NOTE:
Crestron recommends that codes from manufacturers other than
the manufacturer of the device being controlled be used to avoid IR
transmission conflict. For example, if the controlled device is a Sony
DVD player, an acceptable code from any manufacturer (except Sony)
should be used to communicate with the Sony DVD player via the
Crestron control system.
6. Press one or more function buttons on the remote and observe the
“Identify Transmitter” window on the PC.
a) If there is no activity while pressing buttons on the remote, the
code chosen was not an acceptable code or the code could not
be decoded. Repeat steps 5 and 6 with another code.
b) If activity is observed with each button press, the code used was
an acceptable code and the Crestron control system can accept
commands from the universal remote.
Map the Universal Remote
Once communication between the Crestron control system and the
universal remote is achieved, it is necessary to understand what
Operations & Installation Guide – DOC. 6574A
IR Gateway: C2N-IRGW-F
•
11