Crestron BiAmp AudiaFlex Quick Start Manual Download Page 3

 

 
 
 
 
 

 

Partner: BiAmp 

Model: AudiaFlex & Nexia 

Device Type: DSP 

 

FEEDBACK: 

 

Volume_Gauge 

A  Analog value indicating the current volume level. To be displayed using a gauge on a 

touch panel. 

Volume_Level_Sign_Unscaled  A  Analog volume level value. This is the signed dB level. To be displayed using a digital 

gauge on a touch panel. 

Volume_Level_Text 

S  Serial signal indicating the current volume level. This will show from -100.0 to 12.0 

errorReceived 

Digital output that will be set high when the BiAmp sends an error to the module. If this 

output is set high it is an indication of one of a couple of things. The instanceID, device 

type, or indexes entered in the parameter fields are incorrect. The other possible cause 

is that the wrong or no configuration file has been loaded into the BiAmp. Once this 

output is set high, you will still be able to poll for status but no controls will function. 

To_Processor 

Serial data signal to be connected to the From_Modules on the BiAmp Aud 

Nexia Command Processor Serial v7.5.1 module or the BiAmp Aud Nexia 

Command Processor IP v7.5.1 module. 

 

PARAMETERS:

 

Volume_Device_Type 

ASCII  Select the proper device type from the drop down list. 

Volume_Device_ID 

ASCII  Device address automatically assigned after the BiAmp .dap file is compiled 

Volume_Device_Instance  ASCII  Logic Block ID assigned after the BiAmp .dap file is compiled 

Volume_Index_1 

ASCII  Volume index to be controlled. This is the input, channel or output number being 

controlled. 

Volume_Index_2 

ASCII  This used for cross point type devices. Typically, this would be zero. For cross points 

this is the output number for the cross point being controlled. 

Volume_Upper_Limit 

ASCII  This is the upper limit for the volume level being controlled. This is the signed dB value. 

Volume_Lower_Limit 

ASCII  This is the lower limit for the volume level being controlled. This is the signed dB value. 

Volume_Step 

ASCII  Select the volume step value from the dropdown list. Default is 1.0 dB. 

 

TESTING: 

 

OPS USED FOR TESTING:

 

PRO3: 1.501.0013 

SIMPL WINDOWS USED FOR TESTING:

 

4.03.20 

DEVICE DB USED FOR TESTING: 

73.00.001.00 

Summary of Contents for BiAmp AudiaFlex

Page 1: ...er to be controlled Volume_Index_2 is the second index number from the BiAmp software In a lot of cases this will be zero Volume_Upper_Limit is the volume level s upper limit This should be entered as the dB level and negative numbers are allowed Volume_Lower_Limit is the volume level s lower limit This should be entered as the dB level and negative numbers are allowed Volume_Step is the number of...

Page 2: ...is will allow preset values to be sent to the BiAmp Valid range is Volume_Upper_Limit to Volume_Lower_Limit Default range is 100 to 12 NOTE THIS INPUT IS NOT DESIGNED TO BE USED WITH A RAMP SYMBOL IN SIMPL WINDOWS IT IS ONLY DESIGNED TO BE USED FOR PRESET LEVELS Send_New_Level D Pulse to send the volume entered in the New_Volume_Level input This will allow preset values to be sent to the BiAmp Pol...

Page 3: ...dules on the BiAmp AudiaFlex Nexia Command Processor Serial v7 5 1 module or the BiAmp AudiaFlex Nexia Command Processor IP v7 5 1 module PARAMETERS Volume_Device_Type ASCII Select the proper device type from the drop down list Volume_Device_ID ASCII Device address automatically assigned after the BiAmp dap file is compiled Volume_Device_Instance ASCII Logic Block ID assigned after the BiAmp dap f...

Page 4: ...iaFlex Nexia Dialer module where a wait statement in Simpl was not programmed correctly Fixed an issue with the processor module that allowed the processor to lockup if the queue pointers in the wrapped around Changed the method that the processor module uses to collect the InstanceID information The new method should be less confusing to program Added a Simpl Windows gather to the processor modul...

Page 5: ...Partner BiAmp Model AudiaFlex Nexia Device Type DSP ...