background image

Crestron 

BB-4L

 

 

Wall Mount Back Box

 

Mounting the Back Box 

ATTACHED 
MOUNTING PLATE

NOTE: 

BE SURE THE 

ASSEMBLY IS LEVEL 
WHEN MOUNTED

BACK BOX MOUNTING
ENCLOSURE ASSEMBLY
(4505359)

 

Mounted View with Cover Plate (Mounting Example Prior to Drywall Installation) 

ENSURE THAT
THESE SURFACES
ARE FLUSH

SCREWS (4) #04-40 x 2"
PAN HEAD (2018793)

COVER PLATE (2013239)
TO COVER CUTOUT IN DRYWALL
BEFORE TOUCHPANEL IS INSTALLED
(MAY BE REQUIRED BY LOCAL 
BUILDING CODES)

NOTE:

 BACK BOX IS TO BE COVERED WITH 

DRYWALL AND THEN THE CUTOUT MADE 
AROUND THE INSIDE OF THE OPENING. 
BE SURE TO LEAVE THE FOUR TAPPED HOLES 
ON THE FRONT OF THE BOX EXPOSED TO 
ACCEPT THE MOUNTING SCREWS

 

 

Installation Guide - DOC. 6387B 

Wall Mount Back Box: BB-4L  

  5 

Summary of Contents for BB-4L

Page 1: ...Crestron BB 4L Wall Mount Back Box Installation Guide Crestron BB 4L Wall Mount Back Box Installation Guide...

Page 2: ...ssories 7 Resources 8 Industry Compliance 8 Reference Documents 8 Further Inquiries 8 Future Updates 8 Return and Warranty Policies 9 Merchandise Returns Repair Service 9 CRESTRON Limited Warranty 9 A...

Page 3: ...crete or rock use the cutout template available in the post construction kit WMKM 4L or WMKT 4L NOTE For concrete and rock mounting material allow for proper ventilation before mounting the touchpanel...

Page 4: ...te 5 61 in 14 25 cm 3 90 in 9 91 cm 8 47 in 21 52 cm 5 00 in 12 70 cm 5 1 2 in 140 mm 4 1 4 in 108 mm 1 2 in 13 mm 5 8 in 16 mm 1 8 in 2 mm 3 3 4 in 95 mm 3 9 16 in 90 mm 3 25 in 8 26 cm 0 06 in 0 15...

Page 5: ...Crestron BB 4L Wall Mount Back Box Dimensional Drawing Cover Plate 6 00 in 15 24 cm 4 50 in 11 43 cm 0 03 in 0 08 cm Installation Guide DOC 6387B Wall Mount Back Box BB 4L 3...

Page 6: ...OTE If your installation is not on wooden studs be sure to consider the needs of your particular situation For example screw type may vary for steel studs etc Complete the following procedure refer to...

Page 7: ...ENSURE THAT THESE SURFACES ARE FLUSH SCREWS 4 04 40 x 2 PAN HEAD 2018793 COVER PLATE 2013239 TO COVER CUTOUT IN DRYWALL BEFORE TOUCHPANEL IS INSTALLED MAY BE REQUIRED BY LOCAL BUILDING CODES NOTE BACK...

Page 8: ...the NOTE in Mounted View with Cover Plate shown on previous page Installation Complete the installation by either installing the touchpanel leaving the hole open if permitted by local building codes o...

Page 9: ...es MMK 4L Doc 6389 for larger repairs and to fill in larger irregularities around the opening requires plastering TMK 4L Doc 6390 for smaller repairs and to provide a smooth edge at the opening This o...

Page 10: ...ve questions after reviewing this guide please take advantage of Crestron s award winning customer service team by calling the Crestron corporate headquarters at 1 888 CRESTRON 1 888 273 7876 For assi...

Page 11: ...90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer re...

Page 12: ...Crestron Electronics Inc Installation Guide DOC 6387B 15 Volvo Drive Rockleigh NJ 07647 2019474 Tel 888 CRESTRON 11 07 Fax 201 767 7576 Specifications subject to www crestron com change without notice...