12
Crest Audio® Versarray™ Pro series - User GUI Use Instructions
Installation of the Versarray™ Pro series User GUI Software
The software to connect to the Versarray™ Pro 218 Sub speaker system can be found at a link
available on the following URL page:
https://peaveycommercialaudio.com/versarray
Download and install the VR Pro series User GUI Software following the instructions at the web
page referenced. Note that in order for the software to run properly, a copy of the
.NET framework
4.0
(also referred to as the
dotNET framework 4.0
) or higher must be present on your computer.
Instructions and URL’s for where to download this file will be available at the Versarray™ web page:
https://peaveycommercialaudio.com/versarray
Connecting the User GUI Software to the Versarray™ Pro 218 Sub Speaker System for Analog
Signal Input Use
1. Connect appropriate length Ethernet cables to each Versarray™ Pro 218 Sub cabinet (see REAR
PANEL DISPLAY diagram, item #5), and turn on the Power before it is raised into line array position.
The cables need to be at least Cat 5e grade or better. Cat 6 grade cables are recommended for best
results. The Ethernet cables can be daisy chained from one cabinet to the other if more than one
speaker is being connected to or controlled. The longest cable should be run from the bottom of the
array to the PC. Be sure to leave enough spare cable length for the long cable run to accommodate
all the necessary routing, tucking, taping and positioning needed. The input cable from the PC should
be connected to the Primary Ethernet jack, and the cable used to daisy-chain to the next one should
come out of the Secondary Ethernet jack.
NOTE:
If connecting for Dante®, see the Dante Operation section for details on the correct way to
wire up the Versarray™ Pro 218 Sub cabinets. Daisy-chaining as described above can be used with
the proper Dante latency settings, but most professionals will want the maximum performance Dante
is capable of, and this would involve the use of a multi-port gigabit network switch to feed the units in
a star wiring configuration.
2. Connect the other end of the long Ethernet cable to the PC with the Versarray™ Pro series User
GUI software installed on it.
3. Turn on and boot the PC with the Versarray™ Pro series User GUI software.
When the Versarray™ Pro 218 Sub speaker system cabinets are all turned on, the PC should show
a LAN connection notice, before trying to start the Versarray™ Pro series User GUI software. This
can take a minute or so, depending on the exact nature of your PC’s LAN and Ethernet connection
readiness and load time.
Older operating systems may display an on-screen notification, while more recent operating systems
may not show any obvious notification at all. In order to check the status of your network connection,
go to a Control Panel section where the LAN information is displayed, check the
Network and
Internet
section or the
Network Status
window/icon (often located in the lower right hand corner, and
visible once you use the Show Hidden Icons arrow).
THE MOST COMMON CAUSE OF A FAILURE TO CONNECT TO THE POWER AMP MODULE VIA
THE NETWORK IS NOT ALLOWING ENOUGH TIME FOR THE PC TO MAKE THE NETWORK
CONNECTION CORRECTLY BEFORE STARTING THE SOFTWARE!!