Mono Crossover
HF
Out
LF
Out
HP 1
HP 2
LP 1
LP 2
IN
+
-
G
Vosc
CH A
CH B
I/F
ckt
ID
ckt
NexSys®
Module Bus
N-Coder
Data
Port
Gain
Gain
Freq
Freq
Freq
Freq
Trim
Trim
Atten
Atten
B L O C K
D I A G R A M
Crest Audio Inc.
100 Eisenhower Dr., Paramus NJ 07652 USA
TEL
: 201.909.8700
FAX
: 201.909.8744
http://www.crestaudio.com
Printed in USA
N C - M C O
I n p u t P r o c e s s i n g M o d u l e
S P E C I F I C AT I O N S
Crossover frequencies:
80Hz-8kHz
Input impedance:
50k
Ω
Signal-to-noise ratio:
107dB typ.
Common mode rejection:
90dB typ.
Frequency response:
20Hz-20kHz, ± .25dB
Programmable gain range:
0 to -83dB
Voltage gain/input sensitivity:
X20 (26 dB)
X40 (32 dB)
or constant sens. for full output at 0dBu (.775V) in
Connectors:
Balanced inputs and
unbalanced HP /LP daisy-chain outputs
on barrier strip connectors
with 0.325" (8.3mm) screw center
and 0.270" (6.9mm) lug space,
RJ-14 (‘RJ-11 6-pin’) N-Coder data port
Controls:
2 gain attenuators (w/removable knobs)
v. 2.1
4/7/97
*A3300026*
Crest Audio reserves the right to make improvements in manufacturing or design which may affect specification. Crest Audio specification literature is available in electronic form to qualified users.
Contact Crest Audio Inc. for more information. NexSys is a registered trademark of Crest Audio Inc. ©1996 Crest Audio Inc.
C O N T R O L O P T I O N S
The following NC-MCO parameters can be con-
trolled by the hand-held N-Coder, N-Coder/PC
software, or via NexSys software.
N-Coder:
Channel attenuation, phase reverse, trim and fre-
quency for high & low pass
N-Coder/PC software:
Channel attenuation, phase reverse, muting, trim
and frequency for high & low pass
NexSys computer control:
Channel attenuation, phase reverse, solo, muting,
input and output VU metering, trim and frequency
for high & low pass