TROUBLE SHOOTING

NO SOUND ( NO OUTPUT )
  
  @ Please check all connections, cable rounting, shorts & voltages.  
  @ Please check the fuses , If they are  blown, please replace with new one.
  @ Please check whether speakers work well, you can test speakers by connecting to 
     another amplifier 

PROTECTION  

  @ Please check minimum impedance, overheating (thermal), shorts and voltages.
  @ S1 minimum working impedance is 1 ohm.
      S2 and S4 minimum working impedance is 2 ohm stereo or 4 ohm bridged.
  @ If amplifiers shut down due to heat, allow some time to cool down.Please allow for better 
     airflow around the amplifiers.
  @ S1, S2 and S4 working voltage is 8.5V ~ 16Volts
  @ Due to the high efficiency of the amplifier, input signals over 4v (S2 & S4) may cause protect. 
      Check input signal levels.
       
DISTORTION & NOISE

  @ Readjust input level and check the speaker quality at another amplifier
      Replace poor quality speakers with good quality ones
  @ Check amplifiers and headunit’s ground contact. all grounds should be common. 
  @ Check RCA cables for nicks or poor routing. Replace or re-route as needed.
  @ Engine noise is caused by poor grounding of amplifiers, headunit, other components, 
      battery or alternator, so please check all grounding connection.

POOR BASS RESPONSE

  @ Please check speaker cables and polarity.
 

Summary of Contents for SYMPHONY S1

Page 1: ...SYMPHONY OWNER S MANUAL S1 s2 s4 FULL RANGE DIGITAL AMPLIFIER...

Page 2: ...plifiers The design philosophy of SYMPHONY amplifiers and mode of regulation requires that proper installation and load impedance instructions be adhered to at all times Minimum impedance recommended...

Page 3: ...is may be a toggle switch a relay your source unit s remote trigger cables or power antenna trigger cable Connect the remote turn on cable to the REM remote terminal GND GROUND Locate a secure groundi...

Page 4: ...the high pass cutoff point for the speaker outputs HPF can be selected with X over switch located next to it X OVER HPF FULL LPF At HPF High pass filter is activated At FULL It is bypass At LPF Low p...

Page 5: ...MONOBLOCK DIGITAL SPEAKER CONNECTION DIAGRAM 1 MONOBLOCK DIGITAL SPEAKER CONNECTION DIAGRAM 2 4 1ohms 4 2ohms 4 2ohms...

Page 6: ...SS FILTER 50 500 Hz 800 8K Hz Control the low pass filter frequency forthe speaker outputs When setting multiply x1 then the frequencies can be adjusted from 50Hz to 800Hz When setting multiply x10 th...

Page 7: ...S2 FULL RANGE DIGITAL SPEAKER CONNECTION DIAGRAM 1 S2 FULL RANGE DIGITAL SPEAKER CONNECTION DIAGRAM 2 4 2ohms 4 2ohms 8 4ohms 4 2ohms 4 2ohms Stereo Operation Bridged Operation...

Page 8: ...L RANGE DIGITAL SPEAKER CONNECTION DIAGRAM 1 S4 FULL RANGE DIGITAL SPEAKER CONNECTION DIAGRAM 2 4 2ohms 4 2ohms 4 2ohms 4 2ohms 8 4ohms 4 2ohms 4 2ohms 4 2ohms 4 2ohms 4CH Stereo Operation Bridged Ope...

Page 9: ...wn Please allow for better airflow around the amplifiers S1 S2 and S4 working voltage is 8 5V 16Volts Due to the high efficiency of the amplifier input signals over 4v S2 S4 may cause protect Check in...

Page 10: ...aster or third party amplifier modifications This warranty is limited to the amplifier and specifically excludes any incidental or consequential damages connected therewith Warranty is non transferabl...

Reviews: