Before You begin installation

Congratulations and thank you for purchasing your Crescendo amplifiers, the logical choice in mobile audio 
amplification. Your amplifier has been designed and engineered with the highest quality components and 
top of the line workmanship to help you reach the superior sound you are after. 
To achieve optimal performance of your system, please take a few moments to read over this operating 
manual if needed before starting your installation.

Amplifier Location

Allow air circulation around the amplifier.
The amplifier’s compact design allows greater flexibility in mounting. It can be mounted under the seat 
and in the trunk.
When selecting a location, remember that amplifiers generate heat. 
Select a location where air can circulate around the amplifier.
Do not cover the amplifier with carpets or enclose it behind interior trim panels.
Every installation will be a bit different based upon vehicle design, check all locations and placements 
carefully before making any cuts or connections.

Disconnect Battery

Before you begin, always disconnect the battery negative terminal.

If wiring connections are made incorrectly the unit will not operate properly and could be damaged. 
Follow the installation instructions carefully or have the amplifier installed by an authorized dealer.

Things to remember when installing  your 

SYMPHONY 

amplifiers. 

The design philosophy of 

SYMPHONY

 amplifiers and mode of regulation requires that proper installation 

and load impedance instructions be adhered to at all times.
Minimum impedance recommended for S1-v2 and S1 Plus are 1ohm.  
Minimum impedance for S2, S4 & S6 are 2ohm stereo or 4 ohm bridged.
All 

SYMPHONY 

amplifiers are not equipped with fuses. Please use external fuses for all 

SYMPHONY 

amplifiers. 

External fuse ratings are 150A for S1-v2, 300A for S1 Plus 50A for S2, 60A for S4 and 130A for S6. 
These fuse ratings should be sufficient under normal working conditions. However, if the amplifiers are 
overloaded ( see minimum impedance above ) fuses may blow. 
Therefore, please try to avoid operating the amplifiers under these conditions.

1. Mount the amplifiers where air flow is the best.
2. Mount the amplifiers to a solid surface away from vibration, as these amplifiers are heavy and
the vibration can damage the amplifiers.
3. Run 4 gauge wire from the battery, using fuses within 18” of the positive battery terminal.
The fuse is to protect the car and your car audio system from the fire that could be caused by a short circuit.
4. Run 4 gauge  ground wire as short as possible, to the closest chassis ground point. 
Be sure to remove the paint around the chassis ground point to provide a more solid electrical connection.
5. Run a 16 AWG ( or larger ) wire to the remote turn-on lead of the headunit.
6. Connect the speakers as per wiring diagrams in the manual.  
14 AWG or larger speaker wire is recommended.  
7. Mount remote level control in the car where it can be easily reached from the driver’s seat, if desired.
 
 

Important: 

Summary of Contents for SYMPHONY S1 Plus

Page 1: ...SYMPHONY OWNER S MANUAL S1 v2 S1 plus s2 s4 S6 high performance DIGITAL AMPLIFIERs...

Page 2: ...ophy of SYMPHONY amplifiers and mode of regulation requires that proper installation and load impedance instructions be adhered to at all times Minimum impedance recommended for S1 v2 and S1 Plus are...

Page 3: ...toggle switch a relay your source unit s remote trigger cables or power antenna trigger cable Connect the remote turn on cable to the REM remote terminal GND GROUND Locate a secure grounding connectio...

Page 4: ...uencies LOW PASS FILTER 35Hz 250Hz This allows you to tune the response of the amplifier at higher bass frequencies to roll off for a seamless integration into your midbass BASS BOOST 0 9dB This allow...

Page 5: ...S1 v2 S1 Plus DIGITAL MONOBLOCK SPEAKER CONNECTION DIAGRAM 1 S1 v2 S1 Plus DIGITAL MONOBLOCK SPEAKER CONNECTION DIAGRAM 2 4 1ohms 4 2ohms 4 2ohms...

Page 6: ...S FILTER 50 500 Hz 800 8K Hz Control the low pass filter frequency forthe speaker outputs When setting multiply x1 then the frequencies can be adjusted from 50Hz to 800Hz When setting multiply x10 the...

Page 7: ...S2 FULL RANGE DIGITAL SPEAKER CONNECTION DIAGRAM 1 S2 FULL RANGE DIGITAL SPEAKER CONNECTION DIAGRAM 2 4 2ohms 4 2ohms 8 4ohms 4 2ohms 4 2ohms Stereo Operation Bridged Operation...

Page 8: ...L RANGE DIGITAL SPEAKER CONNECTION DIAGRAM 1 S4 FULL RANGE DIGITAL SPEAKER CONNECTION DIAGRAM 2 8 4ohms 4 2ohms 4 2ohms 4 2ohms 4 2ohms 4CH Stereo Operation Bridged Operation 4 2ohms 4 2ohms 4 2ohms 4...

Page 9: ...pass filter frequency forthe speaker outputs Select LPF ON OFF switch MODE CH2 CH4 CH6 Select CH2 mode for a single pair of RCA inputs on CH1 2 to activate all 4 speaker outputs No Y splitter needs S...

Page 10: ...E DIGITAL SPEAKER CONNECTION DIAGRAM 1 S6 FULL RANGE DIGITAL SPEAKER CONNECTION DIAGRAM 2 Bridged Operation 4 2ohms 4 2ohms 4 2ohms 4 2ohms 4 2ohms 4 2ohms 4 2ohms 4 2ohms 4 2ohms 4 2ohms Stereo Opera...

Page 11: ...Please allow for better airflow around the amplifiers S1 v2 S1 Plus S2 S4 and S6 working voltage is 8 5V 16Volts Due to the high efficiency of the amplifier input signals over 4v S2 S4 S6 may cause pr...

Page 12: ...aster or third party amplifier modifications This warranty is limited to the amplifier and specifically excludes any incidental or consequential damages connected therewith Warranty is non transferabl...

Reviews: