HOW TO HOLD:
No water is needed in pan.
1.
Push POWER switch to “ON.” Yellow POWER
2.
LIGHT will come on.
Push the “SET” button on the TEMPERATURE
3.
CONTROL. The TEMPERATURE DISPLAY will
show “SP1” (set point 1).
Press “SET” again and the current set point temperature
4.
will be displayed.
Press the
5.
ADJUST buttons to adjust to the
desired temperature.
Press “SET” to save the temperature setting.
6.
Preheat cabinet for 45 minutes.
7.
Put product into cabinet.
8.
HOLD WITH HUMIDITY:
Fill water pan with HOT water.
1.
Push POWER switch to “ON.” Yellow POWER Light
2.
will come on.
Push the “SET” button on the TEMPERATURE
3.
CONTROL. The TEMPERATURE DISPLAY will
show “SP1” (set point 1).
Press “SET” again and the current set point temperature
4.
will be displayed.
Press the
5.
ADJUST buttons to adjust to the desired
temperature.
Press “SET” to save the temperature setting.
6.
Turn the “HUMIDITY” thermostat to No. 9.
7.
Preheat for 45 minutes.
8.
Turn “AIR” thermostat to desired temperature. (See
9.
thermostat settings below.
10. Put product into cabinet
Air is VERY HOT when door is opened.
NOTES:
Proper food holding temperature is 140°F/60°C or higher.
SOME TYPICAL THERMOSTAT SETTINGS:
Thermostat Setting
Result
Thermostat Setting
Result
Air
Humidity
Cab. Temp.
Humidity
Air
Humidity
Cab. Temp
Humidity
150° F
Off
150° F
N/A
160°F
Med
160°F
50%
175°F
Off
175° F
N/A
160°F
High
160°F
95%
200°F
Off
200° F
N/A
170°F
Low
170°F
15%
170°F
Med
170°F
35%
100°F
3½
100°F
98%
170°F
High
170°F
85%
170°F
Max
170°F
90%
150°F
Low
115° F
98%
200°F
Low
200°F
7%
150°F
Med
150° F
95%
200°F
Med
200°F
15%
150°F
High
150° F
95%
200°F
High
200°F
40%
160°F
Low
160° F
30%
Note:
These settings are based on laboratory conditions and may differ from conditions at point of use. Experiment with
the settings to determine what is best for your application.
WARNING
Figure 3
Yellow
Light
“On-Off”
Switch
“Air”
Thermostat
Thermometer
“Humidity”
Thermostat
R
OFF
POWER
ON
( 0 )
( I )
AIR
7
9
1
2
10
4
3
6
HUMIDITY
PROOF
HOLD
HIGH
LOW
8
MEDIUM
HOLD
5
10
DRY
1
2
3
LOW
4
5
6
MOIST
HIGH
9
8
7
MEDIUM
20
40
190
200
210
0
C
F
100
60
80
20
120
140
220
R
180
105
95
100
90
70
60
160
80