MAINTENANCE INSTRUCTIONS
HOW TO ADJUST THE DOOR LATCH:
1 . For vertical (up and down movement) adjustment:
a . Loosen (2) screws located in magnetic strike .
b . Move strike up or down for alignment to magnet on latch .
c . Tighten screws to secure
2 . For horizontal (greater or lesser magnetic draw) adjustment:
a . Loosen (4) screws in door latch .
b . Move latch forward or backward to adjust magnetism .
c . Tighten screws to secure .
WARNING
IF OVEN GETS TOO HOT OR WON’T SHUT OFF, DISCONNECT
POWER AT BRANCH PANEL. DO NOT UNPLUG CORD!
1 . Cord is unplugged from wall outlet .
2 . Circuit breaker/fuse to wall outlet is blown .
3. Switch is turned off.
4 . Fuse on back of unit is blown .
If unit is
NOT
working, first check the following causes:
NOTE:
Vent fans will not operate until the control compartment requires ventilation to limit temperatures . Replacement
of electrical components must be done by a qualified electrician.
Daily
Drain water pan and clean interior of unit as per instructions in FL-2373-BC
Weekly
Check hinges and latch and adjust as needed per instructions in FL-2373-BC
Monthly
Check that meat probe does not have any fraying wires or exposed conductors .
Replace as needed .
Check that cooling fans are operating when unit is running at cooking temps .
They are controlled by a thermal switch and may not kick on until unit has been
operating for some time .