OPERATING and MAINTENANCE INSTRUCTIONS

Models: 120-PH and 121-PH Series Proof/Hot Cabinets

TROUBLE-SHOOTING CHART:

FAILURE

POSSIBLE CAUSE

1. Yellow light does NOT light.

1a. Circuit breaker/fuse to wall outlet is blown.
1b. Cord is unplugged from wall outlet or cabinet.
1c. Switch is 

“OFF”

.

2. Red light does NOT light.

2a. Thermostat turned “OFF”. 
2b. Thermostat set too low (light comes on when 

heater is on).

3. Unit does not get hot.

3a. Thermostat set too low or is 

“OFF”

.

3b. Water in pan my be low.
3c. Switch is 

“OFF”

.

4. Unit gets too hot or won’t shut off.

4a. Defective electrical parts. 

UNPLUG UNIT FROM WALL OUTLET.

5. Humidity is low

5a. Water in pan may be low
5b. Thermostat set too low

If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.

Instructions for replacing parts are included with the replacement parts kits. 

CAUTION

DELIME OR DESCALE RESERVOIR PARTS AS REQUIRED 
TO PREVENT DAMAGING BUILD-UP. 

WARRANTY COVERAGE MAY BE AFFECTED WITHOUT PROPER CLEANING.

REPLACEMENT PARTS:

Description 

120 Volt 

240 Volt

Proof/Hot Unit ...........................................PHU-18-747-18 .................... PHU-18-747-19
Water Pan w/Heater ...................................

0756-014

 ............................... 0756-015

Water Pan Cover ........................................

1245-001

 ...............................

1245-001

Heater (Water Pan) 1000W ........................

0811-005-K

Heater (Water Pan) 900W ......................................................................... 0811-015K
Heater (Tunnel)..........................................

0811-075

 ............................... 0811-078

Latch, Door ................................................

1136-K

 ..................................

1136-K

Power Cord Kit ..........................................

0810-093

 ...............................

0810-039

Power Light (Yellow) ................................

0766-048

 ...............................

0766-045

Power Light (Red) .....................................

0766-047

 ...............................

0766-046

Relay ..........................................................

0857-097

 ...............................

0857-098

Switch Kit ..................................................

0808-082

 ............................... 0808-010

Strain Relief Collar ....................................5459-004-03 ..........................

5459-004-1

Terminal Block ..........................................

0978-007-K

 ...........................

0978-007-K

Thermostat Kit ...........................................

0848-062-K

 ...........................

0848-062-K

Thermometer Kit .......................................

5238-018-K

 ...........................

5238-018-K

Summary of Contents for 120-PH Series

Page 1: ...you need Thermometer shows the temperature inside the cabinet HOW TO PROOF Push switch to HUMIDITY Yellow power light 1 will come on Turn RESERVOIR THERMOSTAT to 10 Red 2 heater light will come on Preheat cabinet for 30 minutes 3 Put fresh or 4 fully thawed dough into cabinet HOW TO PROOF continued Turn RESERVOIR THERMOSTAT to 9 and 5 close the door CAUTION NOTE The cabinet temperature will drop t...

Page 2: ...lear the tie rod TO TURN UNIT OFF Push switch OFF NOTE Check water level in water pan if you are proofing longer than 90 minutes Fill with clean hot water Cleaning hints Wipe up spills as soon as possible 1 Clean cabinet regularly to avoid heavy dirt build up 2 Make a test spot with cleaner 3 Follow manufacturer s directions on cleaner 4 Do not mix cleaners 5 Avoid drips and splashes 6 HOW TO CLEA...

Page 3: ... is low 5a Water in pan may be low 5b Thermostat set too low If cause is none of the above refer to our list of Authorized Service Centers FL 1400 Instructions for replacing parts are included with the replacement parts kits CAUTION DELIME OR DESCALE RESERVOIR PARTS AS REQUIRED TO PREVENT DAMAGING BUILD UP WARRANTY COVERAGE MAY BE AFFECTED WITHOUT PROPER CLEANING REPLACEMENT PARTS Description 120 ...

Page 4: ...12 WIRING DIAGRAMS ELECTRICAL SPECS MODEL 0747 018 110 120V 2025 W 1Ph 50 60Hz AC Service ELECTRICAL SPECS MODEL 0747 019 220 240V 1925 W 1Ph 50 60Hz AC Service LEGEND H4 HEATER TUNNEL H1 HEATERS AIR H3 HEATER RESERVOIR PL1 PILOT LIGHT RESERVOIR AMBER PL2 PILOT LIGHT RESERVOIR RED PL3 PILOT LIGHT AIR AMBER PL4 PILOT LIGHT AIR RED SW SWITCH TB TERMINAL BLOCK TH1 THERMOSTAT AIR TH2 THERMOSTAT RESERV...

Reviews: