MAINTENANCE INSTRUCTIONS

Models: 1000HHSS2D Hot Cabinets

Cleaning hints: 

1. Wipe up spills as soon as possible.

2.  Clean cabinet regularly to avoid heavy  

dirt build-up.

3. Make a test spot with cleaner.

4. Follow manufacturer’s directions on cleaner.

5. Do not mix cleaners.

6. Avoid drips and splashes.

7. Do not use “Cres Clean” on plastic parts or labels.

BEFORE CLEANING CABINET: 

1. Allow the cabinet to cool.

2. Do NOT use abrasives or harsh 

chemicals.

 

 

HOW TO CLEAN THE UNIT:

Soil

Cleaner

Method

Dirt

Mild Detergent* and hot water, or 

mild abrasive cleaner.

1. Wipe with soft, damp cloth.

2. Rinse with hot water.

3. Wipe Dry.

Steam (no strong alkaline additive)

1. Rinse after steam cleaning.

2. Wipe Dry

Fingerprints, grease, oil

Mild abrasive cleaner.

Oily or waxy cleaner.

Apply with soft, clean cloth.

Chemical oven cleaner.

Follow oven cleaner manufacturer’s 

instructions

Water Spots

Mild abrasive cleaner.

1. Apply with soft, clean cloth.

2. Wipe with damp cloth.

*Mild detergent includes soaps and non-abrasive cleaners.

Note

: Gaskets are removable for cleaning.

TROUBLE-SHOOTING CHART: 

FAILURE:

POSSIBLE CAUSE:

1.

 

Switch light or control display does NOT 

light up.

1a. Circuit breaker/fuse to wall outlet is blown

1b. Cord is unplugged from wall outlet.

1c. Switch is 

“OFF.”

1d. Switch or control defective.

2. Unit gets too hot or won’t shut off.

2a. Relay or control defective. 

UNPLUG UNIT FROM WALL OUTLET

3. Unit does not heat.

3. Defective heater, relay, or control.

4. Thermostat control reads “err oo”

4. Temperature probe defective.

WARNING