background image

Ovens

FL-2374-D

Rev. 2 (6/14)

Page 8 of 13

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

5925 Heisley Road • Mentor, OH 44060-1833

REPLACEMENT PARTS

Include all information on nameplate when ordering parts

ITEM DESCRIPTION

500-CH-SS-D

750-CH-SS-D

1000-CH-SS-SPLIT-D

16. Casters, Rigid

0569-288

0569-288

0569-306-R

17. Casters w/ Brake

0569-287-B

0569-287-B

0569-306-B

18. Door Assembly

1221-570-K

1221-576-K

1221-573-K

19. Door Gasket

0861-270

0861-269

0861-267

20. Hinge Kit (2)

0519-109-K

0519-109-K

0519-109-K

21. Door Latch Kit

1006-122-01-K

1006-122-01-K

1006-122-01-K

22. Latch Strike Kit

1006-122-02-K

1006-122-02-K

1006-122-02-K

23. Pan Slides

0692-202

0692-203

0692-200

24. Drip Pan

1017-109

1017-117

1017-115

25. Drip Tray

1017-107

1017-118

1017-111

26. Wire Shelf

1170-030-SS

1170-217

1170-212

27. Clear Drip Pan

1017-058

1017-058

1017-058

28. Strainer

1052-094

1052-094

1052-094

      Probe, Food

0848-112

0848-112

0848-112

      Probe Connector

0848-106-02

0848-106-02

0848-106-02

ELECTRICAL REPLACEMENT PARTS

CABINET REPLACEMENT PARTS

ITEM DESCRIPTION

CMP Part No.

1. Switch (On/Off)

0808-125

2. Digital Control

0848-092-08-K

3. Switch, Fan

0848-034

4. Relay

0857-136

5. Terminal Block (Input)

0852-109

6. Terminal Block

0852-091

7. Switch, toggle

0808-020

8. Vent Fan (240V)

0769-174

    Vent Fan (120V)

0769-165

9. Fan Guard

0769-167

ITEM DESCRIPTION

CMP Part No.

10. Heater Kit 240V, 1325W

0811-296-K

      Heater Kit 120V, 1000W

0811-295

-K

11. Hi-Limit

0848-033

12. Power Cord (3000W, 1Ph)

0810-173-01-K

      Power Cord (3000W, 3Ph)

0810-164-02

      Power Cord (2000W, 1Ph)

0810-065-1

13. Strain Relief

0818-050

14. Transformer

0769-197

Summary of Contents for 1000-CH-SS-SPLIT-D

Page 1: ...d MAINTENANCE MANUAL for Cres Cor RADIANT OVENS Ovens FL 2374 D Rev 2 6 14 Page 1 of 13 5925 Heisley Road Mentor OH 44060 1833 500 CH SS D 500 CH AL D 750 CH SS D 1000 CH SS SPLIT D Cabinet model numb...

Page 2: ...ow to Clean the Unit 7 Replacement Parts 8 Illustration Ovens 9 Trouble Shooting Guide 10 Wiring Diagram 120V 11 Wiring Diagram 208 240V Single Phase 12 Wiring Diagram 208 240V Three Phase 13 SERVICE...

Page 3: ...Amps Volts Amps Ph Wire Volts NEMA 500CHSSD 500CHALD 750CHSSD 1000CHSSSPLITD 208 240 208 240 1 1 1 1 60 60 60 60 14 11 14 13 208 240 208 240 20 20 20 20 1 1 1 1 2 2 2 2 208 240 208 240 6 20P 6 20P 6 2...

Page 4: ...the opposite side FOR FIRST TIME OPERATION ONLY A new oven needs to burn off factory oils and glue before it s first use Do NOT load food into oven until this has been done 1 Push switch to ON the lig...

Page 5: ...60 C and 220 F 104 C 2 Push the knob to set the temperature 3 The control automatically goes to the TIME mode Setting the time or Food Probe 1 If NOT using the Food Probe a Turn the control knob to th...

Page 6: ...pe Note You can set Quick Recipes for recipes that you use often This way when you press a recipe group button and press start that recipe will start cooking without searching for the recipe number Re...

Page 7: ...oap or mild detergent and water 1 Sponge on with cloth 2 Rinse Stubborn Spots Stains Mild abrasive made for Stainless Steel 1 Apply with damp sponge or cloth 2 Rub lightly Burnt on Foods or Grease Che...

Page 8: ...Pan 1017 109 1017 117 1017 115 25 Drip Tray 1017 107 1017 118 1017 111 26 Wire Shelf 1170 030 SS 1170 217 1170 212 27 Clear Drip Pan 1017 058 1017 058 1017 058 28 Strainer 1052 094 1052 094 1052 094 P...

Page 9: ...73 7267 Fax 800 822 0393 www crescor com 5925 Heisley Road Mentor OH 44060 1833 REPLACEMENT PARTS Include all information on nameplate when ordering parts INSULATION SIDE PANEL HEATER WIRE COVER 1 2 3...

Page 10: ...erate See Note 1 Vent fan switch defective 2 Vent fan defective 1 Replace 2 Replace Control will not switch from COOK to HOLD timed mode 1 Oven is in PROBE mode 2 Oven control defective 1 Cancel recip...

Page 11: ...AIR LOOKING AT REAR t AIR PROBE SOLID STATE RELAY AIR HEATER L1 T1 A2 A1 HIGH LIMIT TERMINAL BLOCK brown blue TERMINAL BLOCK brown blue GROUND POWER CORD TERMINAL BLOCK brown blue VENT FAN FAN SWITCH...

Page 12: ...LOOKING AT REAR t AIR PROBE SOLID STATE RELAY AIR HEATER L1 T1 A2 A1 HIGH LIMIT TERMINAL BLOCK brown blue TERMINAL BLOCK brown blue GROUND POWER CORD TERMINAL BLOCK brown blue VENT FAN FAN SWITCH HAM...

Page 13: ...AR t AIR PROBE SOLID STATE RELAY AIR HEATER L1 T1 A2 A1 HIGH LIMIT VENT FAN FAN SWITCH TERMINAL BLOCK blue brown TERMINAL BLOCK brown blue GROUND POWER CORD HAMMOND WHITE BLACK BROWN ORANGE RED YELLOW...

Reviews: