background image

2 of 2

CI321X01R0_B

www.creelighting.com 

© 2019 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content is 
subject to change. See www.creelighting.com/warranty for warranty and specifications. Cree

®

 and the Cree logo are registered 

trademarks of Cree, Inc.  THE EDGE

®

 is a  registered trademark of Cree Lighting, A company of IDEAL INDUSTRIES. 

STEP 10:

Unhook the installation support 
cables and tuck the cables 
neatly into the housing.

STEP 11:

Place luminaire on mounting 
box by sliding the luminaire so 
that the (4) Luminaire Mount 
Screws on the mounting box are 
at the end of each slot in the 
housing. See 

Figure 3.

STEP 12:

Tighten (4) Phillips screws and 
verify luminaire is secure. See 

Figure 1

.

ELECTRICAL CONNECTIONS

STEP 1:

Make the following Electrical Connections to the terminal block:

a.  For 120/277V connect the black fixture lead to the voltage supply 

lead (Hot 1 for 208/240V wiring).

b.  For 120/277V connect the white fixture lead to the neutral supply 

lead. (Hot 2 for 208/240V wiring).

c.  Connect the green or green/yellow ground lead to the green lead.

   LINE
OR HOT 1

GREEN

LINE-BLACK

GROUND-GREEN

NEUTRAL-WHITE

NEUTRAL

OR HOT 2

SUPPL

Y WIRING

LUMINAIRE

7.0"

6.0"

Mounting

2.4"

Mounting

3.4"

5

(4) Mounting Holes 

for 3/16" Customer 

supplied Screws

Keyhole Knockouts- Provided for 

Alignment Over Junction Box 

ONLY

1/2"  Conduit Knockout

2-2/12" Inspection Knockout Hole for 

Mounting Over Recessed Junction Box

4

3.500" Min. Box Mounting

Ht. to Achieve 3" Required

Clearance Above Fixture

Reviews: