background image

1 of 2

LPN000100_D

INSTALLATION INSTRUCTIONS

CR150

INCLUDING CR150-650L, CR150-1000L, CR150-2000L

STEP 1:

Remove CR150 fixture from the packaging.  Remove and save the 
two screws from the power supply lid. Remove the lid from the 
power supply exposing the terminal block. See 

Figure 1.

STEP 2:

Ensure power is turned off at main power source. If replacing 

existing fixture, remove existing fixture from the ceiling opening and 
disconnect wires. For new installation, cut a 150-175mm diameter 
opening into ceiling for CR150. 

STEP 3:

When Installing With Conduit:

 Remove and discard sheathed 

wire installation plate. Select conduit installation plate and remove 
knockout holes with screw driver. See 

Figure 2.

Locate power wires inside the ceiling opening. Pull wires through 
conduit. Install and fasten conduit with conduit nut onto supplied 
conduit installation plate. Continue to STEP 4.

 

When Installing With Sheathed Wire:

 Select sheathed wire 

installation plate  and discard conduit installation plate. See 

Figure 2.

TO INSTALL:

1

CR150

8

IP44

IP20

6

7

1

75mm

47,5mm

CAUTION - Tc location 

shown is 55°C max

9

63°C

Conduit Installation Plate

Sheathed Wire Installation Plate

IMPORTANT SAFEGUARDS

WARNING 

- Risk of Electric Shock. Disconnect power at fuse or circuit breaker 

before installing or servicing. 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1.  Each luminaire shall be installed only in its intended manner and orientation

2.  Luminaire designed for use only on 220-240V, 50/60 Hz, protected circuits from 

Circuit Breaker / Fuse Panel. 

3. 

Recommended fixed wiring size is 0.75-2.5 sq. mm. Recommended strip length 

is 7mm. 

4. 

Installation should only be performed by qualified personnel. 

5.  The luminaire is to be installed in accordance with the national installation 

regulations and electrical codes. 

6.  Lens portion of luminaire is suitable for IP44 locations. Remainder portion of 

luminaire is only suitable for IP20 locations. 

7.  Suitable for locations with maximum ambient of 35°C. 

8.  Suitable for damp locations..

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

CEILING OPENING, CEILING THICKNESS COMPATIBILITY

• 

CR150 

fixture is designed to be compatible with 150-175mm diameter ceiling openings.

• 

 Either fixture should be installed in non-insulated ceilings ranging from 1-25mm thick and with maximum above ceiling temperature of 
35°C.

• 

Not all existing ceiling openings that meet these requirements will be compatible with the 

CR150

. To ensure compatibility, a test 

installation should be conducted.

FOR AUSTRIALIA (AU) AND NEW ZEALAND (NZ) ONLY, THE 

FOLLOWING INSTALLATION IS REQUIRED:

1.  Minimum clearance for insulation installation around the product per the “CA80” 

requirements in accordance with the NZ requirements as shown below:

2

2. 

Building insulation abutting the luminaire must meet the following requirements :

a. 

Insulation abutting the luminaire needs to be of a type that can retain its structural integrity when exposed to maximum surface 

temperatures of this luminaire (90C) for CA80

b. 

Abutting insulation must be able to withstand 30 second needle flame test as per ASNZS 60695.11.5

c. 

Loose fill insulation as per NZS 4246 is not permitted to abut or cover this down light “batt” style insulation is ok subject to complying to “b”

FOR ALL OTHER COUNTRIES, THE FOLLOWING INSTALLATION IS REQUIRED:

1.  Luminaire not suitable for covering with thermally insulated material. 
2. 

Ensure adequate free air space (>50mm) around the entire luminaire and its power supply unit. 

Reviews: