INSTALLATION INSTRUCTIONS

C-AR SERIES 

http://lighting.cree.com/warranty      |     866.924.3645     

CAUTIONS

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety 

precautions should always be followed including the 

following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before 

installation.

DANGER

 – Risque de choc – Couper l’alimentation 

avant l’installation.

2.  This luminaire must be installed in accordance with the 

NEC or your local electrical code. If you are not familiar 

with these codes and requirements, consult a qualified 

electrician. 

Ce produit doit être installé conformément à NEC ou votre 

code électrique local. Si vous n’êtes pas familier avec ces 

codes et ces exigences, veuillez contacter un électricien 

qualifié.

.

3.  SUITABLE FOR WET LOCATIONS. 

CONVIENT AUX EMPLACEMENTS MOUILLES.

SAVE THESE INSTRUCTIONS 

FOR FUTURE REFERENCE

 

Inner Trunion

(Assembles to the Housing)

Adjustment Screw and Holes

Lock Washer

between Trunions

Outer Trunion

Sealing Washers

Cord Grip

Align these 

Two Trunion Holes

Back Box

(Cross Section View)

Hex Nuts

Hex Bolts

Cord

Lock 

Washers

Gasket for 

Cord Grip

Nut for

Cord Grip

FIGURE 1

NOTE: 

Fixture is only UL listed for downlight orientation.

NOTE:

 Use this fixture installation sheet for installing. DO NOT refer to 

the mounting accessory sheet for installing.
1. 

Remove the (4) bolts and sealing washers holding the fixture back 

box to the housing using a 9/16" socket.

2.  Disconnect the 2 halves of the quick disconnect on the housing 

cord to allow the back box to be separated from the housing.

3. 

Attach U-bracket to fixture back box as shown in 

Figure 1

. Make 

sure sealing washers are under bolt heads.

U-BRACKET MOUNTING

4. 

Pass bolts from inside of fixture back box through back box and 

U-bracket.

5.  Slide (2) lock washers over bolts.
6.  Secure U-bracket to back box with (2) 5/16" nuts. Tighten nuts to 

132 in-lbs (15 N•m)

7.  Insert end of cord supplied with U-bracket kit through cord grip 

so that the ends extend from the threaded end of the cord grip by 

approximately 4". Tighten cord grip firmly to cord.

8.  Remove nut from cord grip. Pass threaded end of cord grip 

through wall of back box from outside to inside of box. Make sure 
gasket for cord grip is on outside of back box

9.  Tighten nut on threaded end of cord grip to secure cord grip to 

back box. Do not overtighten nut to prevent damage to threads.

10.  Reconnect two ends of quick disconnect which were disconnected 

in Step 2.

11. 

Connect cord green wire to fixture ground wire (ground).
Connect cord white wire to fixture common wire (white).
Connect cord black wire to fixture voltage wire (black).

12. 

Reinstall the fixture back box onto the fixture with the (4) bolts and 

sealing washers that were removed in Step 1. Tighten bolts to  
19 ft-lbs. (25 N•m).

13. 

Mount fixture using (2) 3/8" (10 mm) bolts appropriate for mounting 

surface. See 

Figure 2.

14.  Make wiring connections to cord leads per the 

Fixture Wiring

 

section.

15.  Use the locking screws provided to secure the U-bracket in a 

fixed position, being sure to line up a set of locking holes in both 

brackets. Securely tighten both center bolts on sides of U-bracket.

FIGURE 2

Summary of Contents for C-AR Series

Page 1: ...t 2 Disconnect the 2 halves of the quick disconnect on the housing cord to allow the back box to be separated from the housing 3 Attach U bracket to fixture back box as shown in Figure 1 Make sure sealing washers are under bolt heads U BRACKET MOUNTING 4 Pass bolts from inside of fixture back box through back box and U bracket 5 Slide 2 lock washers over bolts 6 Secure U bracket to back box with 2...

Page 2: ... and tilt fixture to desired angle Tighten 3 8 bolt to 19 ft lbs 25 N m 13 See Fixture Wiring section for electrical connections 14 If photocell accessory is used locate it in the cover of the fixture wiring chamber See photocell installation sheet for details 15 Replace fitter wiring chamber cover and tighten 2 screws that were removed in Step 6 NOTE Fixture is only UL listed for downlight orient...

Page 3: ...n against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radi...

Page 4: ...soporte en U a la caja posterior de la luminaria de la forma que se muestra en la Figura 1 Asegúrese de colocar arandelas de sello debajo de las cabezas de los pernos 4 Pase los pernos desde el interior de la caja trasera de la luminaria a través de la caja trasera y el soporte en U MONTAJE DEL SOPORTE en U 5 Deslice las 2 arandelas de seguridad sobre los pernos 6 Fije el soporte en U a la caja tr...

Page 5: ...9 ft lb 25 N m 13 Consulte la sección Cableado de la luminaria para ver las conexiones eléctricas 14 Si se usa el accesorio de fotocelda ubíquelo en la tapa de la caja de conexiones de la luminaria Consulte los detalles en la hoja de instalación de la fotocelda 15 Vuelva a colocar la tapa de la caja de conexiones y apriete los 2 tornillos que retiró en el paso 6 NOTA La luminaria está listada en U...

Page 6: ... a fin de brindar una protección razonable contra interferencias perjudiciales en instalaciones residenciales Este equipo genera usa y puede irradiar energía de radiofrecuencia Si no se instala y usa de acuerdo con las instrucciones puede causar interferencias perjudiciales para las comunicaciones radiales Sin embargo no existe garantía de que no se produzca interferencia en una aplicación en part...

Page 7: ...s les têtes d écrous 4 Passez les boulons de l intérieur de la partie arrière du luminaire à travers cette dernière et le support en U MONTAGE DU SUPPORT EN U 5 Glissez 2 rondelles de blocage sur les boulons 6 Fixez le support en U à la partie arrière avec 2 écrous de 7 9 mm 5 16 po Serrez les écrous à 15 Nm 132 po lb 7 Insérez l extrémité du cordon fourni avec la trousse du support en U à travers...

Page 8: ...n de 9 5 mm 3 8 po à 25 Nm 19 pi lb 13 Voyez la section Câblage du luminaire pour les connexions électriques 14 Si une photocellule est utilisée comme accessoire placez la dans le couvercle de la chambre de câblage du luminaire Consultez la fiche d installation d une photocellule pour plus de détails 15 Replacez le couvercle de la chambre de câblage du montant et serrez les 2 vis retirées à l étap...

Page 9: ...nable contre les interférences nuisibles dans une installation résidentielle Cet équipement génère utilise et peut émettre de l énergie de radiofréquence et si non installé et utilisé selon les instructions il peut causer une interférence nuisible aux radiocommunications Par contre il n existe aucune garantie que les interférences ne se produiront pas dans une installation en particulier Si cet éq...

Reviews: