STEP 5:

Remove the pink EPE plastic foam from over the LEDs by 
removing each piece of blue tape.

STEP 6:

Bring the retrofit side panel up to the existing troffer pan and 
connect the ground wire on the back of the side panel to the 
retrofit main assembly as shown in 

Figure 6.

 Tuck the ground 

lead up into the main assembly.

STEP 7:

Insert the edge of the side panel, that is opposite of latches, 
between the existing troffer pan and t-grid. Then insert 
the other side into the retrofit main assembly by engaging 
the 2 latches on the side panel into the 2 slots on the main 
assembly. See 

Figure 6 and 7.

NOTE:

 Make sure not to pinch any wires, all wires should be 

tucked up inside the main assembly.

STEP 8:

Install the lens over the LEDs by putting the lens flat edge 
over one side of the bracket located on the main assembly. 
While pushing on the middle of the lens, to widen the lens, 
insert the other flat end of the lens over the other side of the 
bracket. See 

Figure 8 and 9.

5

6

7

8

Sliding End 

Cap

Retrofit Main Assembly 

Bracket

Retrofit Side Panel

Ground Wire

Retrofit Side Panel Latch

Lens

Retrofit Main 

Assembly Bracket

Lens Flat 

Edge

Safety Cable

Edge of Side Panel insert into 

Existing Troffer Pan

Ground Wire 

Attached to Main 

Retrofit Assembly

Lens

9

Summary of Contents for ZR-RK Series

Page 1: ...as a result of the kit installation Do not leave any other holes open in a wiring enclosure or electrical component Seulement les trous indiqués dans les photographies ou les dessins peuvent être faits ou altérés pour l installation du kit upgrade LED Ne laissez aucun trou ouvert dans le compartiment électrique 6 WARNING To prevent wiring damage or abrasion do not expose wires to the edge of sheet...

Page 2: ... of the existing troffer pan between the existing troffer pan and the t grid Then slide the other end of the main assembly into the existing troffer pan Gently push the full main assembly up into the existing troffer pan Ensure that the end cap is flushed with the ceiling grid and that there are no gaps NOTE Do not let go off the assembly until Step 2 is finished STEP 2 While holding onto the retr...

Page 3: ... latches on the side panel into the 2 slots on the main assembly See Figure 6 and 7 NOTE Make sure not to pinch any wires all wires should be tucked up inside the main assembly STEP 8 Install the lens over the LEDs by putting the lens flat edge over one side of the bracket located on the main assembly While pushing on the middle of the lens to widen the lens insert the other flat end of the lens o...

Page 4: ...e equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interfe...

Page 5: ...luminaire lead to the switched supply switched c Connect white luminaire lead to the neutral supply lead d Connect ground bare or green yellow lead to the incoming ground lead from the conduit or screw the green ground lead to the existing troffer pan if the safety ground is made through the pan on the existing troffer e If 0 1 10V Dimming is used connect the violet lead to the supply positive dim...

Reviews: