Creda TIDN24P001 Installation And Operating Instructions Download Page 2

24 Hour Timer

IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Installation

Switch the heater off and remove the plug-in protective cover
from the right hand side of the thermostat unit at the back of
the heater. Remove the 24-hour plug in timer from its box and
plug it into the slide in compartment now exposed. Switch the
heater on at the mains supply.

Mode Selection

There are three different operating modes. Press 

MODE

 to

cycle through these:

MAN OFF 

- heating is

permanently Off – see

Fig. 1

.

This is also the default
screen.

MAN ON 

- heating is

permanently On - see

Fig. 2

.

AUTO 

- runs the

programmed times - see

Fig. 3

.

Set Time

Press the PROG key
once to set time. The  
appears on the screen
(see 

Fig. 4

) and the hours

can be set using the   
keys. Press ENTER
when finished setting the
hours. Set minutes using
the     keys and press
ENTER.

Time is now set.

MODE

PROG

ENTER

12:13

MAN       OFF

Fig. 1

MODE

PROG

ENTER

12:13

MAN   ON

Fig. 2

MODE

PROG

ENTER

00:00

AUTO                ON

Fig. 3

MODE

PROG

ENTER

00

:00

MAN       OFF

Fig. 4

Set Program

A maximum of four
program periods can be
set as follows;
Press 

PROG 

twice (see

Fig. 5

). The program

settings can now be
entered (starting with 

P1

ON

, where 

P1 ON

 is the

first ON time setting).

a) set P1 ON time:

Set the hours using  

 and press 

ENTER

. Then set the

minutes using     and press 

ENTER

.

NOTE: Time is set in 10 minute blocks.

Then set

 P1 OFF 

time

:

Set the hours using     and press 

ENTER

.

Then set the minutes using     and press 

ENTER

. If only

one program is required, press 

PROG 

now to return to default

display 

OR

b) 

set

 P2 ON and OFF 

times: repeat procedure as ‘a)’ above.

c) 

set

 P3 ON and OFF 

times: repeat procedure as ‘a)’ above.

d) 

set

 P4 ON and OFF 

times: repeat procedure as ‘a)’ above.

After programming 

P4 

the

 

default screen is automatically

displayed. To leave program settings unchanged press

ENTER 

continually. At any time during programming, pressing

PROG 

will exit to the default display.

Timer must be in AUTO mode to run Set Programs.

Key Lock

To lock the keypad press

ENTER 

and release, then

press 

MODE

 within 1

second (see 

Fig. 6

). The

key symbol   will appear
on the screen when the
keypad is locked.
To unlock the keypad
repeat the action above.
If any of the buttons on the
keypad are pressed when
it is locked, the light will automatically come on.

The Advance Function

When in 

AUTO

 mode, if   is pressed for longer than 2 seconds

the program will advance to the next programmed setting.
When the 

ADVANCE

 function is active 

ADVANCE

 will be

displayed on the screen (see 

Fig. 7

).

To cancel advance press   for longer than 2 seconds e.g. If
present time is 14:00 and
P1 ON is at 17:00 and P1
OFF

 

is 19:00, if   is held

for 2 seconds then

ADVANCE

 appears on

the screen. The heater
comes on and remains on
until 19:00. 

ADVANCE

disappears from the
screen at 17:00 as set
program is then running.

MODE

PROG

ENTER

00:00

AUTO    

ON    

P1

    

Fig. 5

MODE

PROG

ENTER

00:00

MAN      OFF 

   

Fig. 6

MODE

PROG

ENTER

00:00

ON 

   

AUTO

  

ADVANCE

Fig. 7

Installation and Operating Instructions

TIDN24P001   Issue 1

Reviews: