Creda Spa300c Installation And User Manual Download Page 6

 

 

 

 

c) ELECTRICAL 

 

WARNING: THIS SHOWER MUST BE EARTHED.  

 

The electrical installation must be in accordance with the current BS.7671 (IEE Wiring Regulations)                 
and “Part P” of the Building Regulations and/or local regulations. 

 

1.

 

The shower unit is designed for a single phase AC electrical supply. 

Please check the rating plate on the unit to see what details apply to your shower.                                        

AS A

 

GUIDE ONLY    (* Only applies if external earth impedance is less than 0.35 Ohms) 

                                                                  

 

Rating 

Cable Sizes 

Fuse / MCB                Cable Length 

6.0mm² 

10.0mm² 

40A Type B MCB 

27m Max.  
45m Max.                 

8.5 / 7.8kW  240 / 230V

 

6.0mm² 

10.0mm² 

45A BS.1361 fuse 

12m Max.

*

  

21m Max.

*

   

6.0mm² 

10.0mm² 

40A Type B MCB 

27m Max.  
45m Max.                 

9.5 / 8.7kW  240 / 230V

 

6.0mm² 

10.0mm² 

45A BS.1361 fuse 

12m Max.

*

  

21m Max.

*

   

10.5 / 9.6kW  240 / 230V 

10.0mm² 

45A BS.1361 fuse 

12m Max.

*

 

 

Remember to upgrade the cable if it runs in thermal insulation in a loft, or for a longer distance. 

 

2.

 

A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with 

the wiring rules. We recommend a ceiling switch mounted in a convenient position. 

 

3.

 

If you have decided to connect the cable on the left hand side then please remove and use the                                     
cable clamp that was provided along the right side (see Diagram 3a/b). 

 

WARNING:  IF LEFT HAND SIDE CABLE ENTRY IS USED, THE MAINS CABLE OUTER SHEATH 

MUST BE STRIPPED BACK TO THE LEVEL MARKED ON THE BACKPLATE, AND ALL 

THREE CONDUCTORS MUST BE FULLY SLEEVED WITH THE SLEEVING PROVIDED 
BETWEEN THERE AND THE TERMINAL BLOCK (SEE DIAGRAM 3a).  

 

 

 
 
 
 

 
 
 

 
 
 

 
 
 

 
 
 

4.

 

Connect cable to terminal block making sure that all the retaining screws are 

VERY

 

TIGHT

 and that no cable insulation is trapped under the screws. 

 

WARNING:  FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD 

RESULT IN FAILURE OF THE TERMINAL BLOCK. 

 

5.

 

Re-fit the detachable bottom section with the two screws if it was removed. 

 

IMPORTANT: Ensure you connect the flying lead from PCB to the front cover.

 

 

6.

 

Re-fit the front cover, and secure by replacing the top and bottom fastening screws. 

Summary of Contents for Spa300c

Page 1: ...IMPORTANT This booklet should be left with the user after installation and demonstration CREDA SPA300C ELECTRIC SHOWER Installation and User Guide...

Page 2: ...um pressure required by the shower is maintained see Effect of Other Water Devices 1 Your shower has been designed for convenience economy and safety of use provided that it is installed used and main...

Page 3: ...g holes at the base of the brackets will be disclosed by removing the plastic fronts See Diagram 4 and instructions supplied with accessories for further details 5 If you have not yet done so remove t...

Page 4: ...p valve 3 The heater can be fed from a header tank provided this has a minimum head of 7 metres 23ft 4 The cold water inlet connection supplied is a plain 15mm straight shank shaft This connector will...

Page 5: ...on of the two are also suitable To aid installation you may find it convenient to move the flexible pressure relief valve outlet assembly by removing the two securing screws If you do please ensure th...

Page 6: ...disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules We recommend a ceiling switch mounted in a convenient position 3 If you have decided to connect...

Page 7: ...the shower as on page 8 or 12 and check Water gets to a satisfactory temperature and water flow can be adjusted by control knob E Knob E has been correctly engaged by ensuring that the knob turns app...

Page 8: ...water to stabilise It is recommended that you do not wholly enter the water spray during this period even if the shower has just been used 5 Once a temperature setting to your liking has been achieve...

Page 9: ...0 9000 420 UK only Water continues to flow when button D pressed to stop This is normal The shower includes a shutdown feature that means the water will continue to flow for up to 7 seconds after stop...

Page 10: ...he shower Effect of Seasonal Incoming Water Temperature Changes The required water temperature is achieved by adjusting the rate of water flow Diagram 7 shows the principle involved in relating temper...

Page 11: ...and on is leaflet The model and serial number are located on the bottom face of the shower Make a note of those numbers here and be sure to quote them if you call for advice Model Number 53 67_ _ _ _...

Page 12: ...showering temperature turn knob E a small amount until you reach the desired showering temperature Turn clockwise for cooler or Turn anti clockwise for warmer 4 When you have finished showering press...