background image

Creda Heating

Design application support 

5

Electric heating is cheaper than gas

Annualised installation costs (based on manufacturers’ quoted average lifetimes 

and typical installation costs for 6 electric panels or 6 wet-radiators and a

gas boiler).

Annual safety check and maintenance costs (to comply with manufacturers’ 

conditions of  guarantee - using lowest priced British Gas service contract to 

include boiler, controls and radiators).

Annual fuel costs (based on guidance from the Energy Saving Trust publication 

CE185 and Npower standard gas and electricity prices on Feb 10th 2008).

Low carbon electricity from renewable sources makes electric
heating the fuel of  the future; but already electric heating is
cheaper than gas.

In recent times all energy prices have risen but none more so than
gas. Creda electric heating is now cheaper over its entire lifetime
than gas, when all the facts are considered.  

Electric heating products cost less to buy in the first place and
are quick and easy to install or upgrade. They offer total flexibility
in the building design, with no complicated pipe runs, which also
leave gaps in the building fabric; a problem when air-tightness is
a key factor in improving the carbon footprint of  a building and
meeting Part L of  the building regulations. Once installed, electric
heating requires virtually no maintenance. Unlike gas there is no
legal requirement for an annual landlord safety certificate.

Year in and year out, electric heating provides instant, responsive
and safe heating on demand. Recent calculations have shown
that when all these factors are taken into account there is a
minimum overall cost saving of  at least 13% a year in comparison
to gas central heating.

Apartments and flats often favour electric heating for all these
reasons. It is the simplest and most cost effective solution for
many hotels, gyms, crèches, nurseries, surgeries, care homes,
offices and shops all over the UK.

Application design

We have over 40 years experience in designing and supporting
electrical heating installations. We are able to offer an expert
application design service for all our products, helping new and
existing customers alike to specify Creda products into real
buildings and live projects, either off-plan, commenced new-build
or refurbishments.

In recent times the proliferation of  environmental legislation and
revisions to Building Regulations, all designed to reduce carbon
intensity and improve energy efficiency, have made the design
process more complex. We are here to help with two levels of
design service.

Level 1:

Our standard design service is free of  charge and will provide a
clear and simple indication of  the products required and the
associated costs. This service can be provided from basic plans
and drawings.

Level 2:

Our enhanced design service incurs a very competitive fee to
cover third-party costs and a small contribution to the work of  our
accredited SAP assessors. In return a dedicated assessor will
provide schematic designs and confirmation of  regulatory
compliance including Part L of  the Building Regulations and a
SAP score, as well as the product requirements and costs to
achieve this. Full architectural drawings are required to complete
this service and work cannot commence without them.

For further information send a description of  your project,
contact details and drawings to [email protected]

Technical services

Our technical services call centre is staffed by a team trained in
diagnosing and rectifying potential concerns over the phone.
If  for any reason they are unable to solve a problem by phone,
they will brief  an engineer on your behalf  prior to the service visit
to ensure that, wherever possible, the problem is fixed first time. 

The team also provides advice on product selection, application,
installation and operation; ensuring maximum value is gained from
selecting a Creda heating product. 

For further information:

Tel: 08709 000430     Fax: 08709 000530

The Building Centre

Building specifiers within easy reach of  Central London can see a
permanent exhibition of  selected Creda products at the Building
Centre in Store Street, WC1E 7BT. The centre also offers a full
library support and literature distribution service for visitors, to
assist them in identifying the most appropriate products for any
given application.

Details of  the Building Centre can be seen by the following the
link at www.creda-heating.co.uk

+44 (0) 1733 456789       www.creda-heating.co.uk

Summary of Contents for Heating Solution

Page 1: ...2008 2009 Product Directory Heating Solutions Cl SfB Uniclass L7522 EPIC L22 56...

Page 2: ...rochure Our advanced heating control options assist in achieving the best possible SAP ratings SAP is the Standard Assessment Procedure for energy ratings and is also used within Part L As pioneers in...

Page 3: ...Thermostatic integral control towel rails 27 Proline II PL Fast response electric ladder towel rails 28 29 TD Traditional style electric towel rails 30 Solarail and LRC Electric towel rails 31 CDF Com...

Page 4: ...inable homes by 2020 The provision of modern facilities are along with the building improvements required to meet this legal obligation brings energy efficiency to the fore Improved air tightness comb...

Page 5: ...ping new and existing customers alike to specify Creda products into real buildings and live projects either off plan commenced new build or refurbishments In recent times the proliferation of environ...

Page 6: ...service Block Assessment Part L 2006 has important rules for setting and achieving the targets in flats and apartments So called Block Assessment allows for all the flats or apartments in a building t...

Page 7: ...an otherwise non compliant building into a fully compliant one However many developers now also see this as the preferred route to meeting other planning requirements or aspirational targets for the u...

Page 8: ...placing this leading technology in heating type 2 with a responsiveness weighting of 0 75 Model Reference Nominal Charge Input Rating Input Rating Number Number Weight Output Acceptance Off Peak Radi...

Page 9: ...temperature cut out Protection Direct Acting automatic reset limit thermostat and automatic reset over temperature cut out Finish white polyester and zinc coated steel with grey base Cable Storage 1...

Page 10: ...ogramming unit supporting setback feature IPX4 rated splashproof Being electronic control is totally silent and reliable Hidden thermostat range limiter feature for additional economy Range of optiona...

Page 11: ...ck time settings of multiple pilot wire linked heaters in up to 4 separate zones see page 20 Control options Control options A range of optional plug in control modules which can be removed from the h...

Page 12: ...ent Eco Response radiators with pure white finish Electronic thermostatic control 0 3 C completely silent operation Pre set background temperature at 5 C below thermostat setting when connected to a p...

Page 13: ...troller 240v mains supply TPRIII E Electronic rotary thermostat Improved economy may be achieved by limiting the thermostat rotational range by means of the mechanical peg and hole feature hidden bene...

Page 14: ...ng for short periods of the day Cost effective they offer an efficient way to extend an existing heating system The ranges come with control options to fulfil the widest range of applications from sin...

Page 15: ...ctor TPRIII M mechanical thermostat without timer 500W 2000W models TPRIII Thermostatic panel heater ranges Advanced control heating systems TPRIII MT mechanical thermostat with 24hr timer 500W 2000W...

Page 16: ...ns borne and pilot wire control options IP24 rated splashproof Control options Newera Style and Newera Electronic panel heaters may be connected as a centrally controlled system using the optional mai...

Page 17: ...stats for comfort and setback Can be used with mains borne or pilot wire controllers as part of a complete heating system Compact attractive design occupying minimum wall space Mains borne and pilot w...

Page 18: ...ection Two level thermal safety overheat Supply 230 240V AC single phase Product Selector Designed to offer economical stylish and safe heating solutions these compact panels can be used in conjunctio...

Page 19: ...re adjustment 24 hours a day 7 days a week Frost protection setting 5 15 C Setback temperature 5 20 C Comfort temperature setting 5 30 C Individual zone measured zone temperature LCD display Can be wa...

Page 20: ...3kW max Contour100 Electronic Panel Heaters Pilot Wire Controller Ref 75 770916 Model PW E4ZC Pilot Wire Interface Ref 75 770915 Model PW E16A 7 Day Timer Pilot Wire Ref 75 770913 Model TPR E7DT 24 Ho...

Page 21: ...full time and temperature adjustment with override and holiday functions TIME 7day multiple time period setting in each zone TEMPERATURE level settings frost 5 15O C setback 5 30O C and comfort 5 30O...

Page 22: ...ded or split tariffs Fanned heating avoids heat stratification Lockable controls cover Negative pressure air movement through the storage core avoids hotspots and heat leakage Elements storage mineral...

Page 23: ...g thermostatic control accurate to within 0 5 C Warmflow gives better heat distribution helping to avoid heat stratification Quiet low velocity Warmflow fan All controls are concealed behind a lockabl...

Page 24: ...d silicaceous aerogel and mineral fibre mat Storage Core high density iron oxide compound Controls Output manually adjustable thermostat controlling output damper Controls Input hydraulic charge contr...

Page 25: ...controllable providing heat quickly when required In built direct element for out of season heating using day rate electricity Fanned heat is faster and more even in distribution particularly near gr...

Page 26: ...ds designed to protect against accidental contact with the hot surface of the heater is available for Creda heaters from our suppliers Norfolk Industries 95 Oak Street Norwich NR3 3BP Please contact t...

Page 27: ...ww creda heating co uk Outline Thermostatic integral control towel rails Model Reference Product Description Rating Height A Width B Depth C OTRC300 75 772710 Outline 30 chrome 300W 855mm 550mm 85mm O...

Page 28: ...he new Proline II range of dry element ladder style towel rails provide much faster heat up than fluid filled models and are lighter and easier to install with no chance of leaks 28 44 0 1733 456789 w...

Page 29: ...80CW 75 774552 Curved white 180W 610mm 453mm 90 100mm 4 4kg PL220CW 75 774553 Curved white 220W 610mm 602mm 90 100mm 7 9kg PL260CW 75 774554 Curved white 260W 843mm 454mm 90 100mm 5 5kg PL360CW 75 774...

Page 30: ...r left or right hand cable entry Control options RFRTK RF remote thermostat kit Enables thermostatic control of electric towel rails using wireless signalling between the remote wall mounted thermosta...

Page 31: ...LRC electric towel rails A range of ladder style fluid filled towel rails finished in chrome All models offer low energy usage whilst maintaining superior heat output Key features Fluid filled for ev...

Page 32: ...h rotary variable thermostat CDF2T 2kW steps back to 1kW after warm up CDF2 Pull cord operated Power on neon indicator Two integral safety devices Fast response downflow heaters offer a low cost solut...

Page 33: ...using wireless signalling between the remote wall mounted thermostat and the receiver unit at the appliance Element stitched black heat type Fan crossflow type Thermoplastic body Powder coated fascias...

Page 34: ...mm long by 2500mm wide this equals 4 5m2 of floor area but the actual amount of underfloor heating required is only 2m2 Add the lengths of runs i e 1 6 1 4 1 1 4 1 metres Calculate the m2 multiply ove...

Page 35: ...re not heating the atmosphere or having the heat blown away in the wind unlike outdoor gas heaters Key features Low running costs as Radiant heat heats solid objects not the air Instant heat cuts the...

Page 36: ...380 415 volt 3 phase supply Control options PIR automatic controller senses movement detected within its range and automatically switch on the heater which will remain switched on for a preset time Th...

Page 37: ...ow maintenance Good vibration resistance Fitted with wire safety guards Robust fitting brackets Ideal for commercial and industrial application where glare free heat is required Element ceramic emitte...

Page 38: ...area Element black heat type Zinc coated steel body matt black end caps Chrome plated steel guards Anodised aluminium reflector Supply 230 240V AC single phase Minimum mounting height 2 metres 300mm m...

Page 39: ...gs Complete with universal mounting brackets for floor or wall fixing and 1m white cable Optional accessories Interlinking kit Available for multiple installations 100mm mounting centres Ref 85 731506...

Page 40: ...hermostatic controller included For remote switching on off and variable thermostatic control Control options For remote switching on off and hot cold air circulation Dual control switch optional Ref...

Page 41: ...ential blower Sunspot 2 25kW The Sunspot is a modular unit almost half the width of the Sunscreen It can be used with a Sunscreen for wider doorways or on its own as a high level wall mounted fan heat...

Page 42: ...r100 Electronic panel heaters TSR Supaslim Combi Storage fan heaters TSR Slimline Electric storage heaters TSF Turbo Commercial storage fan heaters SFHA Sensair Automatic Electric storage fan heaters...

Page 43: ...Right hand connection only Cannot be left hand connection mounted 3 core cable pilot wire capability Straight rail models may be left hand or right hand connection mounted Curved rail models cannot be...

Page 44: ...L 24 L 24 L 18 2M 18 2M 18 2M Up to Comfort 600 600 1000 1000 1250 1250 3m2 Background 600 600 600 1000 1000 1000 Up to Comfort 600 1000 1000 1250 1250 1500 1500 2000 6m2 Background 600 600 1000 1000...

Page 45: ...ted noting possible mounting heights and positions Determine the overall heating requirements WxYxK Total kW loading 1000 Key W Length to be heated in metres Y Width to be heated in metres K Intensity...

Page 46: ...150mm 6 200mm 8 Floor type Solid Timber Insulated Glazing Single Double Triple Window frames Metal Timber UPVC Property type House Bungalow Office or Flat storey type Ground Intermediate Top Usage pa...

Page 47: ...ically switch it off when you don t Creda products used in conjunction with control options should be put in setback mode to save energy 15 Use a shower if you have one save time money and water Visit...

Page 48: ...orley Way Peterborough UK PE2 9JJ t 44 0 1733 456789 f 44 0 1733 310606 www applied energy com aeinfo applied energy com www creda heating co uk C019 August 08 All Creda Heating products unless otherw...