Solscreen Air Curtain
Electrical
The installation of this appliance should be carried out by a competent
electrician and be in accordance with the current IEE wiring regulations.
Fixing Positions
This appliance may be either wall-mounted or fi xed to a ceiling – see Fig. 2
for various fi xing positions and ‘Installation’ see section below, for details on
fi xing. Heaters may be mounted end to end for wide doorways.
Installation
Using the wall mounting bracket as a guide (see ‘a’ in Fig. 3) mark off the
hole positions on the wall or ceiling (see Dim 424 in Fig. 1). A minimum
height of 1.8metres is required from fl oor to bracket. Fix the bracket in
position by following steps as described under the heading ‘Wall or Ceiling
Mounting’.
Wall or Ceiling Mounting Solid brick or concrete block walls must be drilled
and plugged (using a spirit level as a guide ensure bracket is level) Solid
brick or concrete block walls must be drilled and plugged (using a spirit
level as a guide ensure bracket is level), due to different types of wall
constructions fi xings are not included, ensure the correct fi xings are used.
The plug must be located in the solid part of the wall, not just in the plaster
layer. The plug must be located in the solid part of the wall, not just in the
plaster layer. For panelled internal walls or ceilings, it is best to locate the
studding, position the heater fi xing bracket accordingly and use screws
supplied. If it is not possible to locate the studding, use type M5 Rawlplug
inserts, making the 10mm holes with a drill rather than a bradawl or a
screwdriver. Locate the heater on the mounting bracket ensuring that the
pozi-head screws are fully engaged in the slots of the bracket.It is important
that the serrated metal washer (a) is located between the heater holding
bracket (b) and the wall mounting bracket (c). Adjust heater to the required
angle then fi rmly tighten the fi xing screw (d) inside the endcap (e) using a
cross-head screwdriver (f) as shown in Fig. 4.
Electrical connection
Release the screws at either end of the air-outlet grille (see Fig. 5) to gain
access to the terminals for connection of the supply cable - see Fig. 6.
Insert the mains cable down the outside of the back panel (not on inside)
and through the rear entry cable clamp and make connection as shown
in Fig. 6 (see also Fig. 7 for detailed views of cable clamp). Connection
to fi xed wiring should be made through an adjacent minimum 20 amp
double-pole switch. Re-secure the outlet grille. Ensure that the air-curtain
is securely fastened and that the supply cable is fi rmly clamped before
operating the appliance.
Operation
Switch on electricity supply to the heater.
Switching the switch marked ‘I’ energises the blower.
Select ‘l’ and the smaller switches marked as required (see Fig. 8)
Settings
I
: Fan ‘On’
I +
: Half heat
I +
+
: Full heat
Thermal Safety Cut-outs
The power supply to the heating elements will be interrupted if one or a
combination of the following abnormal events occurs.
1. Air inlet or outlet grilles are obstructed.
2. Internal ventilation is impaired due to build up of dust and fl uff.
3. Blower unit stalls.
Note
: If the cut-out operates, the fan may continue to run impairing the
performance of the heater. If this occurs, turn off unit immediately and
follow the reset procedure below.
Procedure for resetting cut-out(s)
Establish cause and eliminate.
Follow the steps below to reset cut-out(s)
1. Disconnect power supply.
2. Pass small fl at head screwdriver through Air Inlet/Outlet panel ‘B’ to button
side of cut-out (see ‘g’ in Fig. 10) avoiding contact with element (see ‘e’ in
Fig. 10).
3. Press reset button in direction shown in Fig. 10 to reset cut-out. (Cut-out
clicks when reset)
4. Remove screwdriver carefully.
5. Turn on supply.
If the cut-out continues to operate intermittently, the heater should be
switched off and a service agent contacted.
Maintenance
WARNING : Disconnect the heater from the mains supply before
carrying out maintenance.
This product is designed to require no
maintenance. If operated in an extremely dusty environment it may
however be necessary to carefully brush clean the air-inlet grille from time
to time.
Recycling
For electrical products sold within the European Community
At the end of the electrical products useful life it should not be disposed
of with household waste. Please recycle where facilities exist. Check with
your Local Authority or retailer for recycling advice in your country.
Cleaning
WARNING: ALWAYS DISCONNECT POWER SUPPLY before cleaning
the heater
. Do not use detergents, abrasive cleaning powders or polish of
any kind on the heater. External appearance can be maintained by wiping
occasionally with a damp cloth; for stain removal, a weak soap solution can
be applied with a cloth and the surface wiped dry. Care must be taken to
avoid any moisture ingress into the product. Ensure that dust or fl uff does
not accumulate inside the heater as this could lead to overheating of the
element. Use a vacuum cleaner to remove any fl uff which does accumulate.
After Sales Service
Your product is guaranteed for one year from the date of purchase. Within this
period, we undertake to repair or exchange this product free of charge (subject to
availability) provided it has been installed and operated in accordance with these
instructions. Your rights under this guarantee are additional to your statutory
rights, which in turn are not affected by this guarantee. Should you require after
sales service you should contact our customer services help desk on 0844
879 3588. It would assist us if you can quote the model number, series, date of
purchase, and nature of the fault at the time of your call. The customer services
help desk will also be able to advise you should you need to purchase any
spares. Please do not return a faulty product to us in the fi rst instance as this may
result in loss or damage and delay in providing you with a satisfactory service.
Please retain your receipt as proof of purchase.
Creda Heating
Millbrook House
Grange
Drive
TEL:
0844
879
3588
Hedge
End
FAX:
0844
879
3583
Southhampton
WEBSITE:
www.credaheating.co.uk
SO30
2DF
Republic
of
Ireland
Tel:
01
842
4833
© GDC Group Ltd,
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of GDC Group Ltd.