Creda CSQ15 Installation And Operating Instructions Manual Download Page 2

Installation and Operating Instructions

Models Covered:
CSQ15
CSQ30   

 

 

 

 

 

 

CSQ45   

 

 

 

 

 

 

 

 

08/51150/0  Issue 0

IMPORTANT

These instructions should be read and carefully retained by the user.

 

The installation of these appliances must always be carried out by a competent 

 

electrician and be in accordance with the current wiring regulations and relevant 

Building Regulations.
The radiated heat from the heater is considerable and must be taken into account 

 

when locating the heater. Ensure that the heater is not used in close proximity to 

the skin or eyes.
Always isolate the heater from the supply before undertaking any maintenance 

 

work on the appliance.
The CSQ range of heaters are designed for internal use only. They are not rated as 

 

flame-proof and must not be used when flammable dusts, gases, or vapours, etc. 

are likely to be present in the atmosphere. If in doubt, advice should be sought 

from the Health and Safety Executive inspectors or local fire officers.
Quartz lamps are extremely fragile and must be handled with extreme care at all 

 

times. Avoid touching the surface of the quartz sleeve with bare fingers. If the 

sleeve is accidentally touched remove the finger print with a soft cloth moistened 

with methylated spirits.
This heater must not be located immediately above or below a fixed socket outlet 

 

or connection box.

WARNING – THIS APPLIANCE MUST BE EARTHED.

SPECIFICATIONS

The Creda CSQ range is available in 1,2 and 3 lamp models with outputs of 1.5kW, 

3.0kW and 4.5kW respectively. The 4.5KW model is supplied as a dual voltage unit and is 

suitable for use on 230V ~ 1PN and 400V ~ 3PN supplies.

General Data:

Model No.

No. of Lamps

Rating

(kW)

Voltage

(V)

Weight

(kg)

CSQ15

CSQ30

CSQ45

1

2

3

1.5

3.0

4.5

230V ~ 1PN

230V ~ 1PN

230V ~ 1PN

3.7

4.3

5.8

Material and Finished

Body Casing – Low carbon steel, powder coated.

Reflectors – 1080 (SIA) 99.8% Alum. Electrochemically brightened specular finish.

DIMENSIONS

CSQ15

All dimensions in mm

 

Summary of Contents for CSQ15

Page 1: ...mation which may be of use to you and is available 24 hours a day It includes Operating and installation instructions downloads Request a repair Where to buy our products Literature downloads Heating...

Page 2: ...vice should be sought from the Health and Safety Executive inspectors or local fire officers Quartz lamps are extremely fragile and must be handled with extreme care at all times Avoid touching the su...

Page 3: ...TMENTS 4 FIXING HOLES WIRING DIAGRAMS CSQ15 CSQ30 CSQ45 a External connections for 230V 1PN b External connections for 400V 3PN G Y GREEN YELLOW R RED B BLACK LINKS MUST BE FITTED HEATER WIRING AS OPP...

Page 4: ...lined from the vertical and swivelled care is taken to ensure that the lamps are still horizontal WARNING THESE HEATERS ARE DESIGNED TO BE WALL MOUNTED ONLY THEY MUST NOT BE CEILING MOUNTED THEY MUST...

Page 5: ...g tables show the recommended mounting heights for three typical average intensity requirements Average Radiant Intensity on Heated Area W m CSQ15 CSQ30 QXD45 Height m Throw m Spread m Height m Throw...

Page 6: ...e electricity supply before attempting to work on 1 or near it Always ensure a safe means of access using an access tower or properly supported 2 ladder Some types of quartz lamps run with an internal...

Page 7: ...ntact with water NEVER use the heater where flammable dusts gases or vapours etc are likely to be present in the atmosphere NEVER operate the heater in close proximity to the skin or eyes NEVER allow...

Reviews: