10 

IF WATER IS TOO COLD 

 

Turn knob “C”

 

anti-clockwise 

so that the 

“arrows” are at 11 o’clock and continue turning 
anti-clockwise until you get the water temperature 

of your liking.  

 

Wait 20 seconds

 after each adjustment for the 

water temperature to stabilise. 

 

The final adjustment may be anywhere on the 

scale. 

 

If after turning fully anti-clockwise water is still 
too cold, set shower pattern on shower handset to 

outer or inner pattern only. 

 

IF WATER IS TOO HOT 

 

Turn

 

knob “C” clockwise 

so that the “arrows” 

are at 1 o’clock and continue turning clockwise 

until you get the water temperature of your liking.                                           

 

Wait 20 seconds

 after each adjustment for the 

water temperature to stabilise.  

 

The final adjustment may be anywhere on the 

scale. 

    

If after turning fully clockwise, water is still too 

hot, adjust knob “A” to “Med (medium)” setting 

and re-adjust as above. 

 

Water flow will be reduced on this setting. 

 
 
 
 
 

1.

 

Ensure the electricity and water are turned on to the unit. 

 

2.

 

Your shower has 2 control knobs (see Diagram 6b).                                                                                          

Knob “A” controls the 3 power settings.                                            

The most popular is “High”.  
There are also options for a “Med (medium)”

 

or “Cold” shower (see notes 7 and 8).                                                         

 

Knob “C” controls the temperature of the water. 

 

For this example turn knob “A” to “High” and set

                                                                                                                       

knob “C” so that the “arrows” are at “12 o’clock”. 

 

3.

 

Press button “B”

.                                                                                                                                 

The water will flow and the neon indicator will illuminate.  

 

4.

 

Allow about 20 seconds

 for the temperature of the water to stabilise.                                                         

It is recommended that you do not wholly enter the water spray during                                                                    
this period, even if the shower has just been used. 

 

 

 

 

5. 

Once a temperature setting to your liking has been achieved, knob “C” will rarely need adjusting.                  

You must however take into account required adjustments for variations of incoming mains water 

temperature between summer and winter (see “Effect of Seasonal Incoming Water Temperature                                             

Changes” see page 13).

 

 

6.

 

When you have 

finished

 showering, 

press button “B”

 only.

 

You have no need to adjust knobs “A or C”.                                                                                           

The water will stop flowing neon indicator will go out.                                                                                                                
10.

5kW Variants Only - 

Water will continue to flow for approximately 7 seconds before switching off.

                              

Switch off the electricity at the ceiling switch or local isolator. 

 

7.

 

The “Med (medium)” setting of knob “A” reduces the power used by the shower giving a cooler shower or 

the option of reduced water flow.                                                                                                                    
This option is mainly used for summer usage and if this is used then knob “C” must be re-adjusted.  

 

8.

 

The “Cold” setting of knob “A” will supply water without any heating. 

 

9.

 

Your shower is 

designed to stabilise temperature

 changes caused by water pressure fluctuations           

(see “Effect of Other Water Devices on Incoming Water Supply” see page 13).  

 

WARNING:  DO NOT SWITCH THE SHOWER ON IF YOU SUSPECT IT OF BEING FROZEN.  

WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT. 

 

WARNING:  DO NOT OPERATE THE SHOWER IF WATER IS DISCHARGED FROM THE PRESSURE RELIEF 

VALVE. MAINTENANCE IS REQUIRED BEFORE THE SHOWER CAN BE USED. 

 

WARNING:  CONSIDERATION SHOULD BE GIVEN TO SUPERVISING THE YOUNG, ELDERLY AND THE 

INFIRM WHILST THEY USE THIS SHOWER. 

HOW TO USE YOUR 

AQUAWAVE HERITAGE

  SHOWER (DETAILED) 

Relates to the 

Heritage

 Shower Range ONLY, see unique section for 

Contemporary 

 Range 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 
 

 

 

 

 
 

 

 

6.

 

Re-fit the front cover (see Diagram 4), and secure by replacing the top and bottom fastening screws. 

 

Contemporary Models 

 

a.

 

Ensure the top control knob is aligned to the “ ” position as shown (Diagram 4a). 

 

b.

 

Ensure the “small bar” of the bottom control knob is aligned to 6 o’clock as shown (Diagram 4b). 

 

Heritage Models 

 

a.

 

Ensure the top control Knob is aligned to the “HIGH” position as shown (Diagram 4a). 

 

b.

 

Ensure the bottom control Knob is aligned to 6 o’clock as shown (Diagram 4b). 

 

6c. In the main body of the shower ensure the “raised pip” of the “camshaft”, positioned to accept the  

      top control knob, is set to 12 o’clock (Diagram 4a). 
6d. In the main body of the shower ensure the “bottom gear wheel”, positioned to accept the bottom  

     control knob is turned fully anti-clockwise as shown (Diagram 4b). 

 

6e. Check that the top control knob has been correctly aligned by ensuring that all three power settings 

can be selected.  

 

6f. Check that the bottom control knob has been correctly aligned by turning clockwise and ensuring that 

the knob turns approximately one full turn and when turned back fully anti-clockwise, returns to                  

6 o’clock.   

 

7.

 

Fit the shower hose, and operate the shower first without the handset to flush out particles,                     

fit the handset and then operate the shower as on page 9/10 or 15/16 and check: 

a.

 

Water gets to a satisfactory temperature and water flow can be adjusted by control knob “C”. 

b.

 

Power selection operates in all 3 positions, giving a change in water temperature. 

c.

 

Check again for leaks and that the holes in the shower handset are not blocked. 

 

8.

 

Demonstrate the showers operation to all users. 

Summary of Contents for Aquawave White

Page 1: ...again The water will stop flowing and the neon indicator will go out 10 5kW Models Only Water will continue to flow for approximately 7 seconds before switching off 6 Switch off the electricity suppl...

Page 2: ...to have an open outlet and should only be used with Creda recommended fittings 8 Take care to avoid restricting the outlet of the pressure relief device If water is discharged from the pressure relie...

Page 3: ...be fitted available from us if required 4 Fix the riser rail with screws provided The fixing holes at the base of the brackets will be disclosed by removing the plastic fronts Aquawave Contemporary M...

Page 4: ...ndset until after the front cover and detachable bottom section are fitted WARNING DO NOT FIT A TAP ON THE SHOWER OUTLET WARNING TAKE CARE TO AVOID RESTRICTING THE OUTLET OF THE PRESSURE RELIEF VALVE...

Page 5: ...s from pressure relief valve Check for cause of high pressure and remove it Blockage on outlet e g blocked shower handset Replace the pressure relief disc not covered by guarantee Water does not flow...

Page 6: ...temperature Med medium setting may need to be selected Water too HOT Increase water flow by adjusting knob C clockwise Med medium setting may need to be selected Increase pressure to water supply e g...

Page 7: ...ption of reduced water flow This option is mainly used for summer usage and if this is used then knob C must be re adjusted 8 The Cold setting of knob A will supply water without any heating 9 Your sh...

Page 8: ...anywhere on the dial If after turning fully anti clockwise water is still too cold set shower pattern on shower handset to outer or inner pattern only IF WATER IS TOO HOT Turn knob C clockwise to 1 o...

Reviews: