Creda AquaNoir Installation And User Manual Download Page 8

 

5.

 

Re-fit the detachable bottom section with the two screws if it was removed. 

6.

 

Locate and connect the front cover power supply cable as shown (diagram 5) ensuring that the lead 
is routed away from the heat exchanger.  Take care not to damage the pins when connecting. 

 

7.

 

When re-fitting the front cover  

a.

 

Ensure the top control knob pointer is set to the 12 o’clock position as shown (Diagram 4a). 

 

b.

 

Ensure the pointer of the bottom control knob is aligned to 6 o’clock as shown (Diagram 4b). 

 

c. In the main body of the shower ensure the “raised pip” of the “camshaft”, positioned to accept the  

top control knob, is set to 12 o’clock (Diagram 4a). 

 

d. In the main body of the shower ensure the “bottom gear wheel”, positioned to accept the bottom  

control knob is turned fully anti-clockwise as shown (Diagram 4b).                                                                    
Then secure by replacing the top and bottom fastening screws 

 

e. Check that the top control knob has been correctly aligned by ensuring that all three power 

settings can be selected.  

 

f. Check that the bottom control knob has been correctly aligned by turning clockwise and ensuring 

that the knob turns approximately one full turn and when turned back fully anti-clockwise, returns 

to 6 o’clock. 

 

7.

 

Fit the shower hose, and operate the shower first without the handset to flush out particles,                     
fit the handset and then operate the shower as on page 10 or 16 and check: 

a.

 

Water gets to a satisfactory temperature and water flow can be adjusted by control knob “C”. 

b.

 

Power selection operates in all 3 positions, giving a change in water temperature. 

c.

 

Check again for leaks and that the holes in the shower handset are not blocked. 

 

8.

 

Demonstrate the showers operation to all users. 

 

ASSEMBLY OF ACCESSORIES 

 

 

Diagram 6 - 

Riser Rail and Soap Dish Fitting Instructions 

                   (Refer to the separate fitting instruction sheet packed with the accessories for more details) 

 

 

 

 

1.

 

Establish height of riser rail to suit user requirements. 

 

This should be a maximum of 0.6 metres (2ft) above the level of the heater, see (a) below.     

2.

 

Remove covers from the wall brackets (b).   

 

3.

 

Position the lower bracket and mark the wall for the screw fixing (c).  

Then drill and plug the wall and fix the lower bracket 

without 

the rail location notch. 

4.

 

Fit the rail into the lower bracket. 
Place the remaining bracket 

with

 the rail location notch on top of the riser rail, making sure that the 

rail slot is located into the notch. 
Ensure the hole position is vertically aligned and mark the wall (d). 

Remove the rail and bracket, then drill and plug the wall. 

5.

 

Assemble the height adjuster (e). 

6.

 

Compress the height adjuster assembly and slide onto the rail. 

Fit the hose retaining ring and then the soap dish on the bottom of the rail (f). 

Lock the soap dish into position by tightening the lock nut. 

7.

 

Replace the rail assembly into the lower bracket. 

Refit the top bracket, ensuring the slot in the rail is located into the bracket notch and fix to the wall. 
Slide covers onto both brackets. 

NOTE: The adjustable slider grips the conical nut on the shower hose (g).

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for AquaNoir

Page 1: ...the desired showering temperature Turn clockwise towards the white bands for cooler Turn anti clockwise towards the red bands for warmer 5 When you have finished showering press the start stop button...

Page 2: ...wrong 1 Self Help Creda After Sales Service What to do if things go wrong 2 Professional Service How your AquaNoir Shower Works Guarantee and Contact Details How to use your AquaNoir Shower Summary P...

Page 3: ...t is likely that the pressure switch will turn off the power to the heating elements resulting in a cold shower HOW YOUR AquaNoir SHOWER WORKS Diagram10 3 INTRODUCTION If you experience any difficulty...

Page 4: ...into the unit If top entry is chosen cut away the backplate as shown in Diagram 2a If bottom entry is chosen cut away the walls in the detachable bottom section as shown in Diagram 2b If rear please...

Page 5: ...first Tighten top screw with head protruding about 10mm from the wall and hook the backplate over the screw head This allows for correct and accurate alignment of your shower before marking and fixing...

Page 6: ...bber nozzles or soaking in proprietary lime scale remover and rinsing thoroughly before use actual shower handset not necessarily shown NOTE After use it is normal for some water to drip from the show...

Page 7: ...wer giving a cooler shower or the option of reduced water flow This option is mainly for summer usage and if this is used then knob C must be re adjusted 8 The Cold 1 white band setting will supply wa...

Page 8: ...ature and water flow can be adjusted by control knob C b Power selection operates in all 3 positions giving a change in water temperature c Check again for leaks and that the holes in the shower hands...